2016
DOI: 10.1016/j.joen.2015.12.005
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Cervical and Apical Enlargement Associated with the WaveOne System on the Transportation and Centralization of Endodontic Preparations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
21
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(23 citation statements)
references
References 34 publications
1
21
0
1
Order By: Relevance
“…Mechanical instrumentation includes both enlargement and shaping, and it is important to enhance the effectiveness of irrigants and antibacterial medicaments in eradicating bacteria and eliminating bacterial by-products [2], thus creating adequate space for three-dimensional obturation [2, 3]. Nickel-titanium (NiTi) rotary files were developed in the 1980s and have been associated with shorter instrumentation time and better cutting efficiency when compared with hand instruments [2]. Conversely, NiTi rotary files have larger tapers and can therefore generate increased friction and stress when compared with hand files [4-6].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Mechanical instrumentation includes both enlargement and shaping, and it is important to enhance the effectiveness of irrigants and antibacterial medicaments in eradicating bacteria and eliminating bacterial by-products [2], thus creating adequate space for three-dimensional obturation [2, 3]. Nickel-titanium (NiTi) rotary files were developed in the 1980s and have been associated with shorter instrumentation time and better cutting efficiency when compared with hand instruments [2]. Conversely, NiTi rotary files have larger tapers and can therefore generate increased friction and stress when compared with hand files [4-6].…”
Section: Introductionmentioning
confidence: 99%
“…Apical enlargement is beneficial to reduce the extrusion of debris and the presence of remaining bacteria [2, 22]. Conversely, a smaller canal size can reduce susceptibility to tooth fracture [26, 27].…”
Section: Introductionmentioning
confidence: 99%
“…The clinical validation of any motion is a combination of safety and efficiency (9,(12)(13)(14)23,25,(32)(33)(34). Within the limitations of this study, it can be concluded that the new OGP and OTR motions introduced by the TriAuto ZX2 motor can significantly improve the fatigue life span and the predictability in fatigue life of the tested instruments compared to continuous rotation, thus meeting the safety criteria.…”
Section: Discussionmentioning
confidence: 82%
“…The sample size (n) was based on the previous studies published in the literature. 2,9,17 The teeth had been previously radiographed and were selected based on the presentation criteria of curvature between 10 and 30 degrees in the buccal roots, as determined by the Schneider method. 18 In the interest of the research, teeth with curvature greater than 30 or less than 10 degrees, incomplete root formation, internal or external resorption, previous endodontic treatment, and decayed tissue were discarded.…”
Section: Specimen Selectionmentioning
confidence: 99%
“…The endodontic glide path is used for the exploration and pre-enlargement of the root canal to minimize errors in biomechanical preparation, such as canal transport and deviations. [1][2][3] This procedure can be conducted with instruments made of nickel-titanium (NiTi) alloys with different heat treatments, designs, and conicities. Pre-enlargement provided by the glide path allows the root canal preparation instruments to work with less torsional stress, reducing the risk of instrument fracture.…”
Section: Introductionmentioning
confidence: 99%