2016
DOI: 10.1016/j.chemosphere.2015.08.065
|View full text |Cite|
|
Sign up to set email alerts
|

Comparison of different models predicting the phospholipid-membrane water partition coefficients of charged compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
77
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 60 publications
(78 citation statements)
references
References 48 publications
1
77
0
Order By: Relevance
“…COSMOmic was recently optimized for charged solutes, with regards to the membrane dipole potential [181]. COSMOmic has proved its usefulness for the determination of membrane/water partition coefficients for different solutes [77,126,[179][180][181][182][183][184][185][186][187] and for micelle/water partition coefficients [183,[188][189][190][191]. It was also shown that the results of COSMOmic and MD simulations are comparable [126,182].…”
Section: Cosmomicmentioning
confidence: 89%
See 1 more Smart Citation
“…COSMOmic was recently optimized for charged solutes, with regards to the membrane dipole potential [181]. COSMOmic has proved its usefulness for the determination of membrane/water partition coefficients for different solutes [77,126,[179][180][181][182][183][184][185][186][187] and for micelle/water partition coefficients [183,[188][189][190][191]. It was also shown that the results of COSMOmic and MD simulations are comparable [126,182].…”
Section: Cosmomicmentioning
confidence: 89%
“…However, these systems have been replaced by membrane model systems, which can provide an anisotropic environment that is similar to those observed in cell membranes [215]. Therefore, a better representation of the different interactions that occur in vivo are achieved, including the electrostatic interactions and hydrogen bonds that are not reproduced by octanol/water systems [187,214,215]. Liposomes have been used extensively as model systems, where the determination of the partition coefficient can be carried out by potentiometry, isothermal titration calorimetry, differential scanning calorimetry, equilibrium dialysis and different chromatographic techniques, namely, electrokinetic chromatography and immobilized liposome chromatography [193,[214][215][216].…”
Section: Partition Coefficientmentioning
confidence: 98%
“…No successful applications to environmental and biological processes have been reported so far (Endo and Goss, 2014a). However, since many complex/ multifunction chemicals may ionize in biota, there is a strong need for the investigation of ionic chemicals (Endo and Goss, 2014a;Bittermann et al, 2016). Meanwhile, the development of one-compartment models for ionic compounds indicated improved performance via consideration of partitioning processes to phospholipids (Armitage et al, 2013).…”
Section: Limitationsmentioning
confidence: 99%
“…It must be noted that 28 of the compounds in our database were estimated to be in a predominantly ionized state at pH 7. For these compounds the comparison of the toxicity with the log K OW , constant toxic membrane concentration, and chemical activity may not be valid because it is biased by a potentially limited uptake and different partitioning of the predominant ionized chemical (Bittermann et al ). Therefore, the corresponding compounds have been labeled in Figure and are indicated in Supplemental Data, Tables S1 and S6.…”
Section: Discussionmentioning
confidence: 99%
“…Ionization could principally be considered by replacing the log K OW with the log membrane–water partition coefficient ( K lipw ) and calculating the K lipw for the charged species. However, for neutral compounds the K OW is very similar to the K lipw (Endo et al ), and the partitioning of charged species is often within a factor of approximately 10 compared with the corresponding neutral species for most classes of ionic organic chemicals (Bittermann et al ). Hence, the impact on baseline toxicity and/or toxic ratio calculation of ionizable compounds is limited and may only be observed with higher degrees of ionization.…”
Section: Methodsmentioning
confidence: 99%