Use of a novel polyp “ruler snare” improves estimation of colon polyp size

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
30
3
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(36 citation statements)
references
References 15 publications
2
30
3
1
Order By: Relevance
“…In 63% of these polyps, a size-difference of at least 33% was detected between in situ and postfixation measurements, leading to inappropriate surveillance recommendations in over a third of the cases, regardless of histology and the number of detected polyps. Multiple studies show that in situ measurements differ significantly from postfixation measurements, but there are few studies assessing interobserver variation of in-situ measurements [10][11][12][13]. Most of these interobserver studies have been performed in colon models [11,12] or on video fragments [10,13] and do not specifically address large polyps.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In 63% of these polyps, a size-difference of at least 33% was detected between in situ and postfixation measurements, leading to inappropriate surveillance recommendations in over a third of the cases, regardless of histology and the number of detected polyps. Multiple studies show that in situ measurements differ significantly from postfixation measurements, but there are few studies assessing interobserver variation of in-situ measurements [10][11][12][13]. Most of these interobserver studies have been performed in colon models [11,12] or on video fragments [10,13] and do not specifically address large polyps.…”
Section: Introductionmentioning
confidence: 99%
“…Multiple studies show that in situ measurements differ significantly from postfixation measurements, but there are few studies assessing interobserver variation of in-situ measurements [10][11][12][13]. Most of these interobserver studies have been performed in colon models [11,12] or on video fragments [10,13] and do not specifically address large polyps. Since the proportion of advanced histology increases rapidly with increasing polyp sizes [14], an evaluation of in-situ measurements of large polyps is warranted.…”
Section: Introductionmentioning
confidence: 99%
“…As réguas antropométricas são comuns na área da saúde, utilizadas para diagnósticos cognitivos-mecânicos (ARANHA et al 2017); para auxiliar técnicas forenses (BARNS; KRUGER; TENNANT, 2016); para mensurar anomalias em vísceras (KAZ et al 2016); para acompanhar redução de feridas (SHAH et al, 2013); para avaliar as taxas de crescimento em crianças (CLOUTIER et al, 2013); para analisar a dilatação cervical (NIZARD et al, 2009); para estudar a flexibilidade em cifose torácica (KHALKHALI et al, 2016); dentre outros usos.…”
Section: Introductionunclassified
“…But, besides being time-consuming, some authors showed that there is still a great interobserver variability [6,10,19]. Several other devices to minimize endoscopists' error have been described, such as a graduated ruler [22], a calibrated hood for use in cap-assisted colonoscopy [23,24], a linear probe [25], and a virtual tape measure containing a laserline emitter [26]. Some of the devices described are prototypes, used only in investigation settings and tested in artificial or animal models, and others are not widely available or were not generally adopted in clinical practice.…”
Section: Discussionmentioning
confidence: 99%