2014
DOI: 10.1093/europace/euu224
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy and safety of remote magnetic catheter navigation vs. manual steerable sheath-guided ablation for catheter ablation of atrial fibrillation: a case-control study

Abstract: Although in patients with persistent AF, the recurrence rate is higher in RMN group, the outcome is comparable between RMN and MCN groups in patients with paroxysmal AF. A multicentre prospective randomized study is warranted to clarify this issue.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
17
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(19 citation statements)
references
References 23 publications
1
17
1
Order By: Relevance
“…The results of our analysis revealed a comparable success rate in patients undergoing RMN assisted ablation and MAN catheter ablation. This is consistent with current published literature [16,19,26,27,32]. The flexible catheter used for remote magnetic navigation theoretically facilitates electroanatomic mapping by having a “lighter” tissue touch and thus decreasing distortion of the endocardial border at the catheter tip site.…”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…The results of our analysis revealed a comparable success rate in patients undergoing RMN assisted ablation and MAN catheter ablation. This is consistent with current published literature [16,19,26,27,32]. The flexible catheter used for remote magnetic navigation theoretically facilitates electroanatomic mapping by having a “lighter” tissue touch and thus decreasing distortion of the endocardial border at the catheter tip site.…”
Section: Discussionsupporting
confidence: 91%
“…The flexible catheter used for remote magnetic navigation theoretically facilitates electroanatomic mapping by having a “lighter” tissue touch and thus decreasing distortion of the endocardial border at the catheter tip site. Precise control of the catheter also aids complex ablation procedures by overcoming the difficulty of ablating hard‐to‐access sites as compared with conventional curvature catheter ablation (commonly the right lower pulmonary vein in atrial fibrillation ablation) [32]. Although the lack of contact force and charring of the catheter tip in the era of solid tip remote magnetic navigation catheters resulted in a higher rate of procedural failure initially, this is rarely seen nowadays with the utilization of irrigated tip catheters.…”
Section: Discussionmentioning
confidence: 99%
“…[22][23][24]26 One study showed a trend towards lower long-term success rates with RMN-guided ablation of persistent AF when compared to manual ablation. 21 guided ablation is associated with lower fluoroscopy times, comparable procedure times and comparable success rates when compared to manual ablation. 27,29,30 However, all of these studies are limited by its observational design, which introduces selection bias into the analyses.…”
Section: Amigo Remote Catheter Systemmentioning
confidence: 99%
“…Second, for this study no deflectable sheath was used during ablation, which might improve the procedural success. 21 Third, long-term results are needed to fully assess efficacy.…”
Section: Limitationsmentioning
confidence: 99%