Enantioselective HPLC-DAD method for the determination of etodolac enantiomers in tablets, human plasma and application to comparative pharmacokinetic study of both enantiomers after a single oral dose to twelve healthy volunteers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 32 publications
0
7
0
Order By: Relevance
“…Hewala et al . (), using a Kromasil® CelluCoat® chiral column, reported that resolution between the two enantiomers was 4.25 with the LOQs of ( R )‐etodolac and ( S )‐etodolac being 0.20 and 0.19 µg mL −1 , respectively. The LOQ by HPLC (Zorbax C 18 column) was 0.5 µg mL −1 for the diastereomers of ( RS )‐etodolac prepared with ( S )‐(−)‐ α ‐(1‐naphthyl)ethylamine ( S ‐NEA) (Jin et al ., ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Hewala et al . (), using a Kromasil® CelluCoat® chiral column, reported that resolution between the two enantiomers was 4.25 with the LOQs of ( R )‐etodolac and ( S )‐etodolac being 0.20 and 0.19 µg mL −1 , respectively. The LOQ by HPLC (Zorbax C 18 column) was 0.5 µg mL −1 for the diastereomers of ( RS )‐etodolac prepared with ( S )‐(−)‐ α ‐(1‐naphthyl)ethylamine ( S ‐NEA) (Jin et al ., ).…”
Section: Resultsmentioning
confidence: 99%
“…Hewala et al . () developed and validated an enantioselective HPLC method with diode array detection for determination of etodolac enantiomers in tablets and human plasma using a Kromasil® CelluCoat® chiral column (consisting of cellulose derivative for enantioselectivity). Nevertheless, chiral HPLC columns, for direct analysis, have high cost and relatively poor selectivity (Montes‐Bayón et al ., ).…”
Section: Introductionmentioning
confidence: 99%
“…The stability was assessed by comparing the mean concentrations of the stability sample with theoretical concentrations. The samples were considered stable if the assay results were within acceptable accuracy (100 ± 10%) .…”
Section: Methodsmentioning
confidence: 99%
“…High performance liquid chromatography (HPLC) is by far the most important tool used in the assessment of these parameters. The HPLC methods for etodolac, a nonsteroidal drug (NSAID) used in humans and domestic animals due to its analgesic, antipyretic and antiinflammatory effects, [3] described in literature are mostly used for its determination in tablets [4,5] , human plasma [3,6,7] and in river waters [8] . To the best of our knowledge there are no reports that describe the HPLC monitoring of conversion of 7-ethyltryptophol (7-ET) to etodolac methyl ester (EME), the main precursor in etodolac synthesis, over time on any scale.…”
Section: Introductionmentioning
confidence: 99%