2014
DOI: 10.1371/journal.pcbi.1003629
|View full text |Cite
|
Sign up to set email alerts
|

Messages Do Diffuse Faster than Messengers: Reconciling Disparate Estimates of the Morphogen Bicoid Diffusion Coefficient

Abstract: The gradient of Bicoid (Bcd) is key for the establishment of the anterior-posterior axis in Drosophila embryos. The gradient properties are compatible with the SDD model in which Bcd is synthesized at the anterior pole and then diffuses into the embryo and is degraded with a characteristic time. Within this model, the Bcd diffusion coefficient is critical to set the timescale of gradient formation. This coefficient has been measured using two optical techniques, Fluorescence Recovery After Photobleaching (FRAP… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
58
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(63 citation statements)
references
References 31 publications
(138 reference statements)
5
58
0
Order By: Relevance
“…Subsequently, other reports measured higher diffusion rates [6], [7], calculated to be high enough to explain the SDD diffusion model, and corroborated by a recent biophysical model analysis [8]. Unfortunately, as a major drawback, all the above analyses comprised measurements of diffusion during late nuclear cycles (nc) 10–14 and at the peripheral cytoplasm of the embryo.…”
Section: Introductionmentioning
confidence: 57%
“…Subsequently, other reports measured higher diffusion rates [6], [7], calculated to be high enough to explain the SDD diffusion model, and corroborated by a recent biophysical model analysis [8]. Unfortunately, as a major drawback, all the above analyses comprised measurements of diffusion during late nuclear cycles (nc) 10–14 and at the peripheral cytoplasm of the embryo.…”
Section: Introductionmentioning
confidence: 57%
“…This again highlights the implications that a particular choice of model has on the interpretation of the observations. We based our choice of the parameters that were not estimated in [Sigaut et al, 2014] on the fluorescence lengthscale distribution and on the time it takes for the gradient to be established. Although there are some discrepancies between the results of the simulations of figure 4 and the experimental observations (e.g.…”
Section: Discussionmentioning
confidence: 99%
“…1 in the region where FCS experiments are performed [Sigaut et al, 2014], (20)- (21) yieldα ∼ (0.1 − 0.2)s −1 . Then, through the constraint that the total concentration observed at the anterior pole imposes on θ/α (18), we derive θ.…”
Section: Choice Of Parameter Valuesmentioning
confidence: 95%
See 2 more Smart Citations