2014
DOI: 10.1186/1471-2407-14-200
|View full text |Cite
|
Sign up to set email alerts
|

MicroRNA-484 is more highly expressed in serum of early breast cancer patients compared to healthy volunteers

Abstract: BackgroundPrevious studies have profiled breast cancer compared to normal breast tissue and identified differentially expressed microRNAs (miRNAs). These miRNAs are then assessed in serum of breast cancer patients compared to healthy volunteers. MiRNAs in serum however do not always reflect what is in tissue and important serum miRNAs may be missed. PCR arrays were therefore performed on serum samples from breast cancer patients compared to healthy volunteers with the aim of identifying circulating miRNAs that… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
49
1

Year Published

2016
2016
2019
2019

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(53 citation statements)
references
References 27 publications
3
49
1
Order By: Relevance
“…miR-484 has been identified to be increased in the serum of patients with breast and pancreatic cancer (37). The present results revealed that miR-484 exhibited a 29.7-fold-change in expression in patients with HCC compared with the healthy control.…”
Section: Discussionsupporting
confidence: 47%
See 1 more Smart Citation
“…miR-484 has been identified to be increased in the serum of patients with breast and pancreatic cancer (37). The present results revealed that miR-484 exhibited a 29.7-fold-change in expression in patients with HCC compared with the healthy control.…”
Section: Discussionsupporting
confidence: 47%
“…The remaining 11 miRNAs have never been studied in liver cancer (Table III). Among the 11 differentially dysregulated miRNAs, the function of miR-374a, miR-188-5p, miR-1183, miR-454, miR-324-3p, miR-484, miR-3188, and miR-216b have been studied in human cancers (27,(31)(32)(33)(34)(35)(36)(37)(38)(39)(40)(41)(42)(43); however, the exact function of miR-4271, miR-1471 and miR-3610 remains unclear.…”
Section: Discussionmentioning
confidence: 99%
“…However, previous studies on serum miRNAs have not provided a standardized internal standard. A number of studies have used miR-16 as a standardized internal control for serum miRNA experiments (18,19), however, the expression of serum miR-16 is not stable in a number of tumors (20). Furthermore, in miR-16 derived from red blood cells, the occurrence of hemolysis would result in 20-30-fold increase in blood miR-16, which would affect the results (21).…”
Section: A B C Dmentioning
confidence: 99%
“…Generally, the 382-well format is the most developed for its reduced costs, high throughput, and simple workflow. Moreover, its high sensibility allows the use of a low input of RNA (1-500 ng) [33,34]. Another platform used for miRNAs profile is Microarray technology.…”
Section: Circulating Micrornamentioning
confidence: 99%