2014
DOI: 10.1002/hed.23532
|View full text |Cite
|
Sign up to set email alerts
|

Long‐term experience with reduced planning target volume margins and intensity‐modulated radiotherapy with daily image‐guidance for head and neck cancer

Abstract: The use of reduced (3 mm) CTV-to-PTV margins was associated with reduced late toxicity while maintaining locoregional control.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
40
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(41 citation statements)
references
References 21 publications
1
40
0
Order By: Relevance
“…It may be argued that the extra effort to define a GTV_L and CTV_L would be trivial, since CTV to PTV margins of at least 3 mm are used. Today, less than 3-5 mm expansion margins are not recommended to generate PTV from CTV in SCCHN [13, 14], and this may blur and rule out any delineation uncertainties occurring at the air-tissue border, even though these suggested PTV margins do not take the CTV_Δ into account. In a practical sense, an increased PTV expansion based on the HDs arising from CTV_Δ would overcome this problem without increasing the L-based delineation workload.…”
Section: Discussionmentioning
confidence: 99%
“…It may be argued that the extra effort to define a GTV_L and CTV_L would be trivial, since CTV to PTV margins of at least 3 mm are used. Today, less than 3-5 mm expansion margins are not recommended to generate PTV from CTV in SCCHN [13, 14], and this may blur and rule out any delineation uncertainties occurring at the air-tissue border, even though these suggested PTV margins do not take the CTV_Δ into account. In a practical sense, an increased PTV expansion based on the HDs arising from CTV_Δ would overcome this problem without increasing the L-based delineation workload.…”
Section: Discussionmentioning
confidence: 99%
“…Combining this high degree of conformality with IGRT offers the potential for further reducing toxicity while maintaining local-regional control [ 64 ]. One group successfully reduced PTV margins for patients with head and neck cancer from 5 to 3 mm, reducing the incidence of gastrostomy tube dependence and esophageal stricture but without affecting local-regional control [ 19 ]. Image-guided IMRT may also offer the possibility of dose escalation, which can improve control of some tumors [ 117 ].…”
Section: Higher Conformality/margin Reductionmentioning
confidence: 98%
“…Although radiotherapy could potentially cure NPC, it can also result in significant long-term morbidity. 10 Notably, despite these advances and the consequential improvements in the safety profile of radiotherapy, the toxicity of this treatment modality is still substantial and reducing it further remains an important goal. [3][4][5] These advances include improved radiotherapy treatment design (intensity-modulated radiation therapy [IMRT]) and improved planning and implementation (image-guided radiation therapy [IGRT]).…”
Section: Introductionmentioning
confidence: 99%