2013
DOI: 10.2967/jnmt.112.114827
|View full text |Cite
|
Sign up to set email alerts
|

Receiver-Operating-Characteristic Analysis of an Automated Program for Analyzing Striatal Uptake of 123I-Ioflupane SPECT Images: Calibration Using Visual Reads

Abstract: A fully automated objective striatal analysis (OSA) program that quantitates dopamine transporter uptake in subjects with suspected Parkinson's disease was applied to images from clinical 123 I-ioflupane studies. The striatal binding ratios or alternatively the specific binding ratio (SBR) of the lowest putamen uptake was computed, and receiver-operating-characteristic (ROC) analysis was applied to 94 subjects to determine the best discriminator using this quantitative method. Methods: Ninety-four 123 I-ioflup… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
9
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 23 publications
1
9
0
Order By: Relevance
“…A complete analysis of responders compared to non-responders was not performed. However, survey respondents were divided into a 2:1 ratio of abnormal:normal scan results which is consistent with published data on overall scan results from our patient population [ 17 ]. This suggests that likelihood of response to the survey was not a function of whether the scan result was normal or abnormal.…”
Section: Discussionsupporting
confidence: 63%
“…A complete analysis of responders compared to non-responders was not performed. However, survey respondents were divided into a 2:1 ratio of abnormal:normal scan results which is consistent with published data on overall scan results from our patient population [ 17 ]. This suggests that likelihood of response to the survey was not a function of whether the scan result was normal or abnormal.…”
Section: Discussionsupporting
confidence: 63%
“…Semiquantitative analysis of DAT images using striatal specific binding ratio (SBR) has been shown to be helpful for reporting of clinical cases [38,39]. We calculated SBR as:…”
Section: Definition Of Quantitative Metricsmentioning
confidence: 99%
“…The processing steps have been previously described in detail, and the algorithm includes correction for suboptimal alignment of the head (10,11).…”
Section: Osa Automated Image Processingmentioning
confidence: 99%