“…The fact that temperature, pressure, and relative humidity exhibit 24-hr periodicity is reasonable. However, as stated earlier, sensor testing conducted at LLNL and independent validation and verification sensor testing conducted at the Hydrogen Sensor Testing Laboratory at NREL 15,23,25 showed that these changes had very little effect on the mixed potential sensor baseline. Since the response mechanism of mixed potential sensors relies on electrode kinetics, it is well known that the analyte sensitivity is a strong function of temperature but less so for open circuit voltage (e.g.…”
Section: Resultsmentioning
confidence: 65%
See 3 more Smart Citations
“…The fact that temperature, pressure, and relative humidity exhibit 24-hr periodicity is reasonable. However, as stated earlier, sensor testing conducted at LLNL and independent validation and verification sensor testing conducted at the Hydrogen Sensor Testing Laboratory at NREL 15,23,25 showed that these changes had very little effect on the mixed potential sensor baseline. Since the response mechanism of mixed potential sensors relies on electrode kinetics, it is well known that the analyte sensitivity is a strong function of temperature but less so for open circuit voltage (e.g.…”
Section: Resultsmentioning
confidence: 65%
“…For the first experiment, a tin-doped indium oxide (ITO) based mixed potential sensor was selected due to its level of technology maturation driven by six years of DOE-funded development. [11][12][13][14][15][16][17]22,23 The calibration curve measured in the laboratory, prior to station installation shows that the voltage produced by the sensor and heater control/HIB exhibited the expected logarithmic behavior with increasing hydrogen concentration (Figure 2). The fitted equation, shown in Figure 2, was incorporated into the data acquisition software to convert the logged real-time sensor voltage to real-time hydrogen concentration.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…MPa by a single-stage mode with a voltage of 0.159 V (each cell), an inlet pressure of 10 MPa and the maximum pressure was expected to reach 140 MPa 15 . An EHC design by Grigoriev and co-workers transferred lower pressure into high output pressure up to 13 MPa with 0.01 N/m3 flow rate 16 .…”
Section: Electrochemical Electrolyzer and The Hydrogen Compressormentioning
confidence: 99%