2017
DOI: 10.3390/molecules22112003
|View full text |Cite
|
Sign up to set email alerts
|

19F‐NMR Diastereotopic Signals in Two N-CHF2 Derivatives of (4S,7R)-7,8,8-Trimethyl-4,5,6,7-tetrahydro-4,7-methano-2H-indazole

Abstract: In this paper, we report the anisochrony of the fluorine atoms of a CHF2 group when linked to a pyrazole ring. The pyrazole is part of (4S,7R)-7,8,8-trimethyl-4,5,6,7-tetrahydro-4,7-methano-2H-indazole also known as (4S,7R)-campho[2,3-c]pyrazole, which has two stereogenic centers. Gauge-Independent Atomic Orbital (GIAO)/Becke, 3-parameter, Lee-Yang-Parr (B3LYP)/6-311++G(d,f) calculated 19F chemical shifts of the minimum energy conformations satisfactorily agree with the experimental data. The energy difference… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 62 publications
0
2
0
Order By: Relevance
“…Coupling constants (J) are expressed in Hertz. A JEOL Royal HFX probe head was used for recording the 13 C NMR spectrum as it allows measurements to be taken with the simultaneous decoupling of both 1 H and 19 F nuclei [24]. Atmospheric pressure ionization and electrospray ionization mass spectra were obtained using an Agilent 6130 LC/MSD spectrometer or Agilent 1290 UHPLC system coupled with an Agilent QTOF 6545 mass spectrometer.…”
Section: General Informationmentioning
confidence: 99%
“…Coupling constants (J) are expressed in Hertz. A JEOL Royal HFX probe head was used for recording the 13 C NMR spectrum as it allows measurements to be taken with the simultaneous decoupling of both 1 H and 19 F nuclei [24]. Atmospheric pressure ionization and electrospray ionization mass spectra were obtained using an Agilent 6130 LC/MSD spectrometer or Agilent 1290 UHPLC system coupled with an Agilent QTOF 6545 mass spectrometer.…”
Section: General Informationmentioning
confidence: 99%
“…We have been using gauge‐independent atomic orbital (GIAO)/B3LYP/6‐311++G(d,p) calculated chemical shifts since 1998 . Several kinds of problems were studied using both chemical shifts, δ , and differences between chemical shifts, Δ δ : chiral cyclohexanone derivatives, isomerism, substituent effects, conformational analysis, interpolation between fast interconverting conformers and rotamers, diastereotopic 15 N and 19 F signals, among other topics.…”
Section: Introductionmentioning
confidence: 99%