Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
13
0

Year Published

2005
2005
2018
2018

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 37 publications
(15 citation statements)
references
References 5 publications
2
13
0
Order By: Relevance
“…7. All of the previously measured data [12] fall into the ±5% uncertainty region of the current experiment, and the data are comfortably within ±3% at temperatures close to the melting point. The new method of analysis is felt to be superior, and thus the results reported here are thought to be more accurate than our earlier results because both the measuring technique and equipment have been improved.…”
Section: Resultssupporting
confidence: 74%
See 2 more Smart Citations
“…7. All of the previously measured data [12] fall into the ±5% uncertainty region of the current experiment, and the data are comfortably within ±3% at temperatures close to the melting point. The new method of analysis is felt to be superior, and thus the results reported here are thought to be more accurate than our earlier results because both the measuring technique and equipment have been improved.…”
Section: Resultssupporting
confidence: 74%
“…The measured thermal conductivity for molten indium (purity 99.99%) over a wide range of temperatures is shown in Table I, and the comparison with previous studies and other sources [9][10][11][12][13][14] is illustrated in Fig. 7.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…It has a cylindrical-type setup, meaning the cuvettes for both sample and reference are encompassed by a large number of thermocouples to detect changes in the temperature difference between a sample and reference cuvette (Auroux, 2013;Calvet and Prat, 1963). A calibration run then delivers a function between the measured temperature difference and the heat flow (Sarge et al, 1994). In our previous work, we have demonstrated the feasibility of a sensor for a TianCalvet calorimeter based on low temperature co-fired ceramics (LTCC) technology (Schubert et al, 2016).…”
Section: Introductionmentioning
confidence: 99%
“…Size Effect Anisotropy (nCB [9]) Solid/Solid Transition (s/s) Solid/Liquid Transition (s/l) Superconductor (NbC 0.97 [22]) Active Thermal Conductivity Switch (TCS) Rectification (C 9 H 16 Pt coated CNT and BNNT [24], Asymmetric nano VO2 beam [25], Thermal diode [26]) Electric/ Magnetic/Stress (Bees-wax [6], SrTiO 3 [7], 5CB [8], Cu wire [10], InSb [11], Ferroric-twinned thin film [12]) MEMS (Thermal switch radiator [16], Solid-Liquid thermal interface [17,18]) Thermomechanical (Gas gap heat switch [19]) Thermal (Automatic heat switch [20], Thermal actuator [21]) Wetting (B nanoribbon [13,14], Film/transition boiling transition [15] [44], Te [32,45], InSb / GaSb [46], CdSb [47,48], AlSb [49][50][51], Zn 3 Sb 2 [52]) Semiconductor /Semiconductor (S/S) (LiNO 3 [35], InSe [41]) Metal /Metal (M/M) (Hg [32], K / Zn / Sb / Al / Cu [32,53], Sn [33,53], Ga [32,53,54], In [53,55,56], Cd …”
Section: Bulkmentioning
confidence: 99%