140. Complications and revision rates in minimally invasive Mazor robotic-guided vs fluoroscopic-guided spinal fusions: the MIS ReFRESH prospective comparative study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(15 citation statements)
references
References 0 publications
0
15
0
Order By: Relevance
“…Two recent studies evaluated perioperative outcomes between robotic guidance (RG) and fluoro-guidance (FG) in adult lumbar fusions in the prospectively collected, multicenter MIS ReFRESH database [8,18]. Good et al [8] evaluated a total of 485 patients: 374 in the RG arm and 111 in the FG arm.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Two recent studies evaluated perioperative outcomes between robotic guidance (RG) and fluoro-guidance (FG) in adult lumbar fusions in the prospectively collected, multicenter MIS ReFRESH database [8,18]. Good et al [8] evaluated a total of 485 patients: 374 in the RG arm and 111 in the FG arm.…”
Section: Discussionmentioning
confidence: 99%
“…The current literature suggests that robotic guidance systems can be used to perform reliable and accurate thoracolumbar pedicle instrumentation [5][6][7][8]. However, significant variation between robotic technology over time and individual proprietary robotics systems introduces significant heterogeneity in the body of research.…”
Section: Introductionmentioning
confidence: 99%
“…These ndings have been since validated in studies using the newer Mazor X robotic guidance platform, which has an option of combination with intraoperative CT-based spinal navigation as reported by Khan et al (2018) in 50 patients with degenerative disc disease who underwent robot guided placement of 190 pedicle screws achieving an accuracy rate of 99.5% [22]. Recently, initial results from a high-power multicenter prospective study from the U.S. MIS-ReFRESH compared 374 Mazor robotic-guided to 111 uoroscopic guided minimally invasive spinal fusions and found Mazor robotic-guided had 5.2 fold lower risk of surgical complications and 8.8 fold lower risk for revision surgery [23]. While a similar multi-center prospective comparative European Robotic Spinal Instrumentation study (EUROSPIN) is still ongoing [24].…”
Section: Discussionmentioning
confidence: 99%
“…While navigation and robotic guidance require a technological leap of faith compared with the foundational fluoroscopic guidance technique, they have proven to be safe and reliable techniques for the patient and the surgeon. 80,81 In a multicenter prospective study comparing short term complication and revision rates in MIS robotic guided and fluoroscopic guided lumbar fusions, the robot cases were found to have a 5.8 (95% CI: 3.5-9.6; P < 0.001) times lower risk of surgical complication, a 11.0 (95% CI: 2.9-41.2; P < 0.001) times lower risk for revision surgery, and approximately an 80% reduction (1 min per case) fluoroscopy time. 80 Although robotic and fluoroscopic techniques may have comparable levels of accuracy, the preoperative planning aspect of robotic assistance enables patient-specific simulation to optimize implant size and trajectory.…”
Section: Emerging Applications Minimally Invasive Techniquesmentioning
confidence: 99%