2018
DOI: 10.5935/abc.20180099
|View full text |Cite
|
Sign up to set email alerts
|

Prevention of Sudden Cardiac Death in Hypertrophic Cardiomyopathy: What has Changed in The Guidelines?

Abstract: BackgroundThe new European Society of Cardiology guidelines for hypertrophic cardiomyopathy (HCM) define the estimation of sudden cardiac death (SCD) risk as an integral part of clinical management. An implantable cardioverter defibrillator (ICD) is recommended (class IIa) when the risk is ≥ 6%.ObjectivesTo compare the SCD risk stratification according to the 2011 and 2014 recommendations for ICD implantation in patients with HCM.MethodsRetrospective study including 105 patients diagnosed with HCM. The indicat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

1
0
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 39 publications
1
0
0
Order By: Relevance
“…[24][25][26][27][28] Other studies point out the sensitivity of low score for the recognition of high-risk patients, the capacity to identify cases with an ICD unwarranted and the similar event rates observed in the three risk levels. [29][30][31][32] Our study supports these findings demonstrating that the European model decreases the ICD recommendations compared to the North American guideline, leaves all patients with SCD or appropriate shock unprotected and establishes major agreement in cases not requiring implantation. Nevertheless, the metanalysis of six studies conducted with 7,291 patients demonstrates that in most cases, the five-year SCD risk is properly estimated with the ESC score.…”
Section: Discussionsupporting
confidence: 81%
“…[24][25][26][27][28] Other studies point out the sensitivity of low score for the recognition of high-risk patients, the capacity to identify cases with an ICD unwarranted and the similar event rates observed in the three risk levels. [29][30][31][32] Our study supports these findings demonstrating that the European model decreases the ICD recommendations compared to the North American guideline, leaves all patients with SCD or appropriate shock unprotected and establishes major agreement in cases not requiring implantation. Nevertheless, the metanalysis of six studies conducted with 7,291 patients demonstrates that in most cases, the five-year SCD risk is properly estimated with the ESC score.…”
Section: Discussionsupporting
confidence: 81%