2016
DOI: 10.5935/0103-5053.20160071
|View full text |Cite
|
Sign up to set email alerts
|

Vitamin C Determination by Ultraviolet Spectroscopy and Multiproduct Calibration

Abstract: In this work the vitamin C was determined in industrialized nectar juices through ultraviolet (UV) spectroscopy and multiproduct multivariate calibration, based on partial least squares (PLS) regression. Since samples with different flavors, sugar content (light or not) were together in the model construction, it can be considered as a multiproduct and, due to the heterogeneity of the samples, it was necessary to optimize the calibration and validation sets by outliers elimination. The model was developed and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 20 publications
(24 citation statements)
references
References 21 publications
0
24
0
Order By: Relevance
“…Astringency and bitterness presented the highest correlation coefficients, around 0.8, whereas for other attributes the correlation coefficients are in the range of 0.73 to 0.79. For multivariate calibration models elaborated from results obtained with high variability (as in this case), a correlation coefficient up to 0.7 can be considered satisfactory (Beltrame et al., ; Santos et al., ). In addition, it is known that the correlation coefficient is directly related to the errors embedded in the execution of the reference method, in this case, the “cupping test.” This method of analysis requires preparation of the coffees by percolation of roasted and ground coffee for further analysis and demands tasters with a high level of experience in coffee tasting, capable of distinguishing and quantifying the sensory attributes.…”
Section: Resultsmentioning
confidence: 97%
See 3 more Smart Citations
“…Astringency and bitterness presented the highest correlation coefficients, around 0.8, whereas for other attributes the correlation coefficients are in the range of 0.73 to 0.79. For multivariate calibration models elaborated from results obtained with high variability (as in this case), a correlation coefficient up to 0.7 can be considered satisfactory (Beltrame et al., ; Santos et al., ). In addition, it is known that the correlation coefficient is directly related to the errors embedded in the execution of the reference method, in this case, the “cupping test.” This method of analysis requires preparation of the coffees by percolation of roasted and ground coffee for further analysis and demands tasters with a high level of experience in coffee tasting, capable of distinguishing and quantifying the sensory attributes.…”
Section: Resultsmentioning
confidence: 97%
“…Multivariate models were validated by the determination of the parameters of merit such as accuracy, fit, linearity, residual prediction deviation, sensitivity, analytical sensitivity, and limits of detection and quantification, according to the description presented in the scientific literature (Beltrame et al., ; Santos, Lima, Março, & Valderrama, ).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The successful use of the PLS regression method in the development of multi-product multivariate calibration models is recent (Rambo, Amorim, & Ferreira, 2013;Santos, Março, & Valderrama, 2013;Santos, Lima, Março, & Valderrama, 2015;2016). The use of the PLS method by the industrial sector has been growing and gaining more and more space.…”
Section: Introductionmentioning
confidence: 99%