2016
DOI: 10.5935/0103-5053.20160055
|View full text |Cite
|
Sign up to set email alerts
|

Ibuprofen, Carbamazepine and β-Estradiol Determination Using Thin-Film Microextraction and Gas Chromatography-Mass Spectrometry

Abstract: The use of thin-film microextraction for the extraction of selected pharmaceutical compounds followed by gas chromatography-mass spectrometry detection was evaluated. A segment of polysiloxanes polymer sheet was used as low cost, single use, disposable extraction phase, while Milli-Q water spiked at 20 µg L −1 with the analytes was used for the optimization assays. The controlling parameters for the extraction were optimized via experimental design and it was found that an extraction time of 3 h using a sample… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(5 citation statements)
references
References 19 publications
0
5
0
Order By: Relevance
“…As it can be observed, the developed methodology using BAμE devices coated with sucrose-based hydrochar presents similar or better recovery yields than other miniaturized enrichment techniques, e.g., SBSE coated with PDMS, PA or EG [38] or SBME coated with C8 polymer [39] for the extraction of carbamazepine; TFME coated with PDMS [44] for the extraction of 17--estradiol; SBSE coated with PDMS [42] for the extraction of clofibric acid; SBSE coated with PU [45] for the extraction of diclofenac, gemfibrozil or mefenamic acid. Additionally, the BAμE(npHS)-μLD/HPLC-DAD methodology sensitivity is similar when compared to analogue instrumental systems [37,39,45] and/or some mass spectrometry or tandem mass 26/40 spectrometry instrumental systems [40,44]. On the other hand, instrumental apparatus that employ mass spectrometry or tandem mass spectrometry expectedly presented lower LODs than the proposed technique [38,41,44,46].…”
Section: Performance Comparison With Other Microextraction Techniquesmentioning
confidence: 74%
See 4 more Smart Citations
“…As it can be observed, the developed methodology using BAμE devices coated with sucrose-based hydrochar presents similar or better recovery yields than other miniaturized enrichment techniques, e.g., SBSE coated with PDMS, PA or EG [38] or SBME coated with C8 polymer [39] for the extraction of carbamazepine; TFME coated with PDMS [44] for the extraction of 17--estradiol; SBSE coated with PDMS [42] for the extraction of clofibric acid; SBSE coated with PU [45] for the extraction of diclofenac, gemfibrozil or mefenamic acid. Additionally, the BAμE(npHS)-μLD/HPLC-DAD methodology sensitivity is similar when compared to analogue instrumental systems [37,39,45] and/or some mass spectrometry or tandem mass 26/40 spectrometry instrumental systems [40,44]. On the other hand, instrumental apparatus that employ mass spectrometry or tandem mass spectrometry expectedly presented lower LODs than the proposed technique [38,41,44,46].…”
Section: Performance Comparison With Other Microextraction Techniquesmentioning
confidence: 74%
“…Additionally, the BAμE(npHS)-μLD/HPLC-DAD methodology sensitivity is similar when compared to analogue instrumental systems [37,39,45] and/or some mass spectrometry or tandem mass 26/40 spectrometry instrumental systems [40,44]. On the other hand, instrumental apparatus that employ mass spectrometry or tandem mass spectrometry expectedly presented lower LODs than the proposed technique [38,41,44,46].…”
Section: Performance Comparison With Other Microextraction Techniquesmentioning
confidence: 78%
See 3 more Smart Citations