2015
DOI: 10.5935/0103-5053.20150151
|View full text |Cite
|
Sign up to set email alerts
|

Rietveld Method in the Analysis of Polymorphism in Mebendazole Tablets Acquired in Brazil's Drugstores

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…Since the L1 powder was the source of subsequent tests shown in this work, this characterization is crucial. To perform X-ray powder diffraction, L1 was mounted on a zero-background cell, and the pattern was determined in a Bruker D8 Advance diffractometer equipped with a LynxEye position-sensitive detector [ 33 ]. Using the corrected diffraction data of L1 (C 20 H 27 N 3 O, M = 325.45 g/mol), accurate unit-cell parameters were obtained with a = 17.0520 Å, b = 10.6445 Å, c = 10.5946 Å, β = 102.12°, V =1880.1 (Å 3 ) and density 1.15 g cm −3 .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Since the L1 powder was the source of subsequent tests shown in this work, this characterization is crucial. To perform X-ray powder diffraction, L1 was mounted on a zero-background cell, and the pattern was determined in a Bruker D8 Advance diffractometer equipped with a LynxEye position-sensitive detector [ 33 ]. Using the corrected diffraction data of L1 (C 20 H 27 N 3 O, M = 325.45 g/mol), accurate unit-cell parameters were obtained with a = 17.0520 Å, b = 10.6445 Å, c = 10.5946 Å, β = 102.12°, V =1880.1 (Å 3 ) and density 1.15 g cm −3 .…”
Section: Resultsmentioning
confidence: 99%
“…The lower window of the detector electronics was increased using Si-Einkristalle at the default value of 0.11–0.19 V to minimize the effects of fluorescence. The Rietveld refinement technique [ 83 , 84 , 85 ] with software suite Diffrac TOPAS 4.2 [ 33 , 86 , 87 , 88 ] was used to determine the L1 structure. The single-crystal structure of L1 , used to compare our results, has been previously reported [ 34 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, the polymorphic composition of the bulk drug and formulations marketed in different countries (South Africa, Brazil, Germany) has been analyzed [21,30,[33][34][35]. These studies revealed that all three polymorphic forms of MEB are found in the market.…”
Section: Introductionmentioning
confidence: 99%
“…1). In addition, variable temperature X-ray powder diffraction was employed to study the transformation of Form C into the most stable Form A [20], and the Rietveld method has been used for analysis of MEB polymorphism in commercial tablets of the drug [21].…”
Section: Introductionmentioning
confidence: 99%