Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 0 publications
0
2
0
1
Order By: Relevance
“…The performances of the three proposed Al(III) electrodes were compared with the previously reported ones [21, 22, 28, 29, 48–52]. As shown in Table 3, the coated paste electrode showed superior response to the target cation ions over the other proposed sensors because of the wide linear range, short response time and Nernstian slope.…”
Section: Resultsmentioning
confidence: 93%
See 1 more Smart Citation
“…The performances of the three proposed Al(III) electrodes were compared with the previously reported ones [21, 22, 28, 29, 48–52]. As shown in Table 3, the coated paste electrode showed superior response to the target cation ions over the other proposed sensors because of the wide linear range, short response time and Nernstian slope.…”
Section: Resultsmentioning
confidence: 93%
“…The (dE°/dt) cell values 1.8 × 10 À 5 -1.0 × 10 À 1 2.5-4. 5 10 [22] 19.3 2.5 × 10 À 6 1.0 × 10 À 6 -1.0 × 10 À 1 3.0-8.0 10 [28] 20.0 7.0 × 10 À 6 9.0 × 10 À 6 -1.0 × 10 À 1 2.5-4.0 9 [29] 19.8 4.6 × 10 À 7 1.0 × 10 6 -1.0 × 10 À 1 2.0-6.0 8 [48] 19.4 1.0 × 10 À 6 2.0 × 10 À 6 -2.0 × 10 À 2 3.5-5.0 5 [49] 19.2 1.6 × 10 À 7 4.5 × 10 À 7 -1.6 × 10 À 3 2.2-4.0 15 [50] 15.6 5.1 × 10 À 6 1.0 × 10 À 5 -1.5 × 10 À 2 3.5-4.5 < 10 [51] 19.0 5.5 × 10 À 7 1.0 × 10 À 6 -1.0 × 10 À 1 4.0-8.0 15 [52] 19.6 1.0 × 10 À 5 2.04 × 10 À 5 -1.99 × 10 À 1 2.0-4.0 5.0 This Work MCP 20.0 1.00 × 10 À 6 1.00 × 10 À 6 -1.00 × 10 À 2 4.5-6.5 10 PVC…”
Section: Effect Of Temperatureunclassified
“…Over the past few decades, a variety of organic and inorganic materials have been behaved as ionophores in the literature for the selective detection of Al 3 + ions. Al 3 + selective ion carriers have included thioureas [2], anthraquinones [26], zeolites [27], Schiff base derivatives [28][29][30], imidazoles [31], flavonols [32], crown ethers [33], and salicylidenes [1,34,35]. However, many of these reported electrodes have drawbacks like a constrained pH working range, short shelf time, low sensitivity, slow response, and considerable other metal ions interfering.…”
Section: | Introductionmentioning