2014
DOI: 10.5935/0103-5053.20140082
|View full text |Cite
|
Sign up to set email alerts
|

Preconcentration and Determination of Cadmium in Water and Food Samples byin situSurfactant-Based Solid-Phase Extraction and Flame Atomic Absorption Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…Heavy metals are potentially toxic elements. Thus, they can lead to serious ecological and health problems even at trace levels [1,2]. Cobalt is one of these elements, which surplus in the concentration of it, can cause asthma, gastrointestinal tract irritation, rhinitis, prohibition of enzyme activities, allergic dermatitis vasodilation, and cardiomyopathy [3][4][5].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Heavy metals are potentially toxic elements. Thus, they can lead to serious ecological and health problems even at trace levels [1,2]. Cobalt is one of these elements, which surplus in the concentration of it, can cause asthma, gastrointestinal tract irritation, rhinitis, prohibition of enzyme activities, allergic dermatitis vasodilation, and cardiomyopathy [3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…Among the cited methods, flame atomic absorption spectrometry (FAAS) is a popular technique because its accuracy and precision is high and its cost is low [4,6]. However, the sensitivity of this method limits its application [1,6,7]. To resolve this problem, different separation and pre-concentration techniques such as solidified floating organic drop microextraction (SFODME) [8], hollow fiber-liquid phase microextraction (HF-LPME) [9], dispersive liquid-liquid microextraction [10], and solidphase extraction [4,5,11] have been developed to enrich the analyte concentration to an appropriate concentration.…”
Section: Introductionmentioning
confidence: 99%
“…15 Nevertheless, the detection of metal trace elements in aqueous samples is difficult due to various factors, particularly their low concentration and the matrix effects. 16 Several methods have been reported for the separation and preconcentration of metal ions, such as coprecipitation, 17,18 liquid-liquid extraction (LLE), 19,20 solid-phase extraction (SPE), [21][22][23] and cloud point extraction (CPE). [24][25][26] Recently, coacervates made up of vesicles 27,28 and reversed micelles of alkyl carboxylic acids 29 have been reported, which permit the extraction of analytes in a wide polarity range.…”
Section: Introductionmentioning
confidence: 99%