2013
DOI: 10.5935/0103-5053.20130186
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Voltammetric Determination of Acetaminophen and Caffeine at a Graphite and Polyurethane Screen-Printed Composite Electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 1 publication
0
11
0
1
Order By: Relevance
“…The modified screen-printed electrodes were prepared following the same method of manufacturing already reported for unmodified electrodes [35]. However, here the proportions of graphite powder, PU, and modified silica were fixed at 60, 35, and 5 % (w/w), respectively.…”
Section: Preparation Of the Modified Screen-printed Composite Electrodesmentioning
confidence: 99%
See 1 more Smart Citation
“…The modified screen-printed electrodes were prepared following the same method of manufacturing already reported for unmodified electrodes [35]. However, here the proportions of graphite powder, PU, and modified silica were fixed at 60, 35, and 5 % (w/w), respectively.…”
Section: Preparation Of the Modified Screen-printed Composite Electrodesmentioning
confidence: 99%
“…In previous work, we used a graphite-polyurethane composite electrode in a conventional rod format [4][5][6], and we recently proposed a screen-printed device in which graphite-polyurethane was the basis of an ink used to prepare the working and auxiliary electrodes, as well as the electrical contacts of the reference electrode [35][36][37]. Different to the earlier work, in the present study the ink was modified with 2-benzothiazole-2-thiol organofunctionalized SBA-15 silica prior to the curing process.…”
mentioning
confidence: 99%
“…The same sensor has been earlier evaluated with satisfactory results in electroanalytical determination of acetaminophen [22], simultaneous determination of acetaminophen and caffeine [23] and simultaneous determination of Zn(II), Pb(II), Cu(II), and Hg(II) in ethanol fuel using the SPGPU modified with organofunctionalized SBA-15 silica [24].…”
Section: Introductionmentioning
confidence: 99%
“…The literature showed that several methods were carried out for the analysis of APAP and CAF in their mixture form. APAP and CAF have been determined by spectrophotometric methods [3][4][5][6][7][8][9][10][11][12][13][14], chromatographic methods [15][16][17][18][19][20][21][22][23], voltammetric techniques [24][25][26], Near Infrared (NIR)-chemometric method [27] and Flow-through (FI) ultraviolet plus multioptosensing device technique [28].…”
Section: Introductionmentioning
confidence: 99%