2013
DOI: 10.5935/0103-5053.20130129
|View full text |Cite
|
Sign up to set email alerts
|

Matrix Effect on Butyltin Analysis of Sediments and Fish Tissues by GC-PFPD

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 3 publications
1
4
0
Order By: Relevance
“…In addition, the MBT values in PACS-2 are not certified. Similar results indicating worst analytical performance for MBT have been observed by several studies (Montigny et al, 1998, Aguerre et al, 2000, Santos et al, 2013. However, considering the small differences between Table 2: Analytical curve equation, matrix effect (% ME), square of regression coefficient (R 2 ), instrumental limits of detection (LOD i ), instrumental limits of quantification (LOQ i ), sediment method limits of quantification (LOQ sed ) and biota method limits of quantification (LOQ bio ) for BTs prepared in pure solvent (sol) , sediment matrix (sed) and mussel tissues matrix (bio) .…”
Section: Precision and Accuracysupporting
confidence: 89%
“…In addition, the MBT values in PACS-2 are not certified. Similar results indicating worst analytical performance for MBT have been observed by several studies (Montigny et al, 1998, Aguerre et al, 2000, Santos et al, 2013. However, considering the small differences between Table 2: Analytical curve equation, matrix effect (% ME), square of regression coefficient (R 2 ), instrumental limits of detection (LOD i ), instrumental limits of quantification (LOQ i ), sediment method limits of quantification (LOQ sed ) and biota method limits of quantification (LOQ bio ) for BTs prepared in pure solvent (sol) , sediment matrix (sed) and mussel tissues matrix (bio) .…”
Section: Precision and Accuracysupporting
confidence: 89%
“…Surrogate recovery was above 80 % in all analyses and was used to correct the final extract concentration. Other quality control parameters, such as matrix effect observed and accuracy and precision of applied methods, are described in detail in Santos et al (2013).…”
Section: Methodsmentioning
confidence: 99%
“…The analysis of the BTs followed Santos et al (2013) and Godoi et al (2003), for sediments and SPM, and Cristale et al (2012), for fish tissues. The steps for this analysis included extraction using an acid (acetic acid) and a nonpolar solvent (toluene) followed by derivatization using Grignard reagent and a cleanup step using alumina or Florisil®.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations