2013
DOI: 10.5935/0103-5053.20130077
|View full text |Cite
|
Sign up to set email alerts
|

An Enhanced Electrochemical Sensing Platform Integrated with Graphene Oxide and Iron Hydroxide Colloid for Sensitive Determination of Phloroglucinol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…The relative standard deviation (RSD) value was found to be less than 3%, indicating that the sensing platform provides excellent performance in actual sample detection. 64 The selective biomolecular sensing is the most significant features in practical applications. The interference study was carried out to determine the selectivity of AChE/CSNPs/GCE (0.15 wt %) in detecting ACh in the presence of other biomolecules and inorganic salts such as AA, DA, UA, KCl, NaCl, and MgCl 2 by amperometric measurements, as shown in Figure S16.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The relative standard deviation (RSD) value was found to be less than 3%, indicating that the sensing platform provides excellent performance in actual sample detection. 64 The selective biomolecular sensing is the most significant features in practical applications. The interference study was carried out to determine the selectivity of AChE/CSNPs/GCE (0.15 wt %) in detecting ACh in the presence of other biomolecules and inorganic salts such as AA, DA, UA, KCl, NaCl, and MgCl 2 by amperometric measurements, as shown in Figure S16.…”
Section: Resultsmentioning
confidence: 99%
“…As the data showed a satisfactory recovery range of 99–101.3% in blood serum samples, the present investigations demonstrate high throughput and accuracy in the detection of ACh. The relative standard deviation (RSD) value was found to be less than 3%, indicating that the sensing platform provides excellent performance in actual sample detection …”
Section: Results and Discussionmentioning
confidence: 99%
“…Existing methods in analysing PL such as chemiluminescence, high-performance liquid chromatography (HPLC/MS), and thinlayer chromatography, ion chromatography [8][9][10][11], etc are time-consuming and costly techniques. Few electroanalytical methods were also reported previously such as graphene oxide and iron hydroxide colloid modified glassy carbon electrode [12], ZnO⎯N-(tri methoxy silyl propyl) ethylenediamine tri acetic acid modified glassy carbon electrode [13] Surfactant/MWCNTS/Glassy carbon [14].…”
Section: Introductionmentioning