2016
DOI: 10.5155/eurjchem.7.2.176-181.1391
|View full text |Cite
|
Sign up to set email alerts
|

High temperature CO2 sorption using Ca(OH)2 in pilot scale packed column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
1
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 30 publications
1
1
0
Order By: Relevance
“…Where in this equation formula, D crystal size, đť›˝ : full width at half maximum of the peak (FWHM), 𝜆 represent X-ray wavelength (1.54 Ă…), k is the shape factor which is always close to unity (0.9). As it the apparent peaks in the gure also conrms its agreement with the research and literature published by other researchers to prepare calcium oxide nanoparticles (Preetham et al, 2016) , where the crystallite size of the prepared nanoparticles is estimated to be about 30.991±2 nm at 600 mJ and 34.202±2.2 nm at 500 mJ. Clearly, from Figures 2A and 2B, the highest peak was at 38.02 • for the laser energies 500 and 600 mJ, while the lowest peak was at the angle of 67.59 • , where the anisotropy increases with an increase in particle size.…”
Section: Investigation Of the Crystal Structuresupporting
confidence: 90%
See 1 more Smart Citation
“…Where in this equation formula, D crystal size, đť›˝ : full width at half maximum of the peak (FWHM), 𝜆 represent X-ray wavelength (1.54 Ă…), k is the shape factor which is always close to unity (0.9). As it the apparent peaks in the gure also conrms its agreement with the research and literature published by other researchers to prepare calcium oxide nanoparticles (Preetham et al, 2016) , where the crystallite size of the prepared nanoparticles is estimated to be about 30.991±2 nm at 600 mJ and 34.202±2.2 nm at 500 mJ. Clearly, from Figures 2A and 2B, the highest peak was at 38.02 • for the laser energies 500 and 600 mJ, while the lowest peak was at the angle of 67.59 • , where the anisotropy increases with an increase in particle size.…”
Section: Investigation Of the Crystal Structuresupporting
confidence: 90%
“…Whereas the increase in the laser energy and the interaction of laser pulses with the calcium sample in the beaker had an e ect on the size of the prepared CaO nanoparticles. The crystal size of the synthesized CaO nanoparticles was calculated from the Debye-Scherer equation (Preetham et al, 2016) :…”
Section: Investigation Of the Crystal Structurementioning
confidence: 99%