2021
DOI: 10.4136/ambi-agua.2654
|View full text |Cite
|
Sign up to set email alerts
|

Comparative analysis between the chlorination and ultraviolet radiation methods for the disinfection of bacteria-contaminated water

Abstract: The quality of water for human consumption has been a concern for large organizations and researchers, since the disinfection process, a step of great importance in water treatment plants, has not achieved its proper purpose. There have been frequent reports of the ineffectiveness of bacteria inactivation by the use of chlorine, which is the most used in Brazil, and also due to the formation of by-products such as trihalomethanes and haloacetic acids that are considered toxic to human health. The method of dis… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 7 publications
(6 reference statements)
0
1
0
2
Order By: Relevance
“…Os frascos lacrados foram abertos no momento dos ensaios. Adicionou-se uma gota de hipoclorito de sódio 2,5% em 500mL de cada Frasco Teste (1, 2 e 3), seguindo as recomendações do Ministério da Saúde 10 . Posteriormente, 100mL foram incubados em estufa microbiológica a 35±0,5ºC por 24 horas com meio de cultura Colilert.…”
Section: Medidas De Desinfecção Testadasunclassified
See 1 more Smart Citation
“…Os frascos lacrados foram abertos no momento dos ensaios. Adicionou-se uma gota de hipoclorito de sódio 2,5% em 500mL de cada Frasco Teste (1, 2 e 3), seguindo as recomendações do Ministério da Saúde 10 . Posteriormente, 100mL foram incubados em estufa microbiológica a 35±0,5ºC por 24 horas com meio de cultura Colilert.…”
Section: Medidas De Desinfecção Testadasunclassified
“…Em seguida, foram preenchidas com a água preparada para esse estudo, e as análises foram realizadas. A água foi exposta ao sol por seis horas 10 . Para esse ensaio, a temperatura foi controlada, mantendo-se durante o período avaliado entre 30 e 31ºC, com umidade atmosférica de 75% e índice UV de 9 (muito alto).…”
Section: Medidas De Desinfecção Testadasunclassified
“…UV-LEDs for water disinfection is a promising technology due to several characteristics [ 1 ]: possibility of wavelength selection, non-toxicity (vs. UV lamps containing mercury), instantaneous switch-on-off (no need of warming-up times, possibility of use of pulsed illumination, therefore saving energy), low operating working temperatures (25–30 °C), flexible architecture to design reactors, use of continuous current that allows direct connection with photovoltaic systems, longer lifetime when pulsed illumination is used, etc. [ 2 , 3 ]. But they also face some important constraints that hamper their widespread: economic cost, low efficiency and low power output [ 4 ].…”
Section: Introductionmentioning
confidence: 99%