2021
DOI: 10.21577/0103-5053.20210098
|View full text |Cite
|
Sign up to set email alerts
|

Detection of SARS-CoV-2 in Saliva by RT-LAMP During a Screening of Workers in Brazil, Including Pre-Symptomatic Carriers

Abstract: The coronavirus pandemic has been causing damage to many nations, as public and private health systems deteriorate by the increasing demand. Some infected patients have culturable severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) even though not presenting any symptoms, and therefore, are probably able to transmit it. Correctly diagnosing and isolating infected patients is an important step towards preventing new infections. Current diagnostic methods rely mainly on reverse transcription quantitativ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Other techniques, such as Reverse Transcriptase Loop-Mediated Isothermal Amplification (RT-LAMP), can potentially simplify the execution of the test. The RT-LAMP has been proposed as a reliable diagnostic tool for detecting SARS-CoV-2 20 23 . This method can detect the target genome with high specificity and sensibility in < 40 min, without the need for a real-time thermocycler.…”
Section: Introductionmentioning
confidence: 99%
“…Other techniques, such as Reverse Transcriptase Loop-Mediated Isothermal Amplification (RT-LAMP), can potentially simplify the execution of the test. The RT-LAMP has been proposed as a reliable diagnostic tool for detecting SARS-CoV-2 20 23 . This method can detect the target genome with high specificity and sensibility in < 40 min, without the need for a real-time thermocycler.…”
Section: Introductionmentioning
confidence: 99%
“…Each technique has its own merits and limitations. Colorimetric biosensors are portable, easy to use and rapid in response, with potential for large-scale POCT in remote locations ( Li et al, 2020 ; Alafeef et al, 2021 ; dos Santos et al, 2021 ; Ferreira et al, 2021 ). As a typical example, the lateral flow assay (LFA) is a type of these biosensors that uses conjugated gold nanoparticles, fluorescent molecules, or quantum dots for visual sensing of color changes.…”
mentioning
confidence: 99%
“… LEAD ( de Lima et al, 2021 ) Nasopharyngeal/oropharyngeal and saliva SARS-CoV-2 spike protein The sensor enables on-site SARS-CoV-2 detection within 6.5 min, the sensitivity of which is comparable to the gold-standard methods (LOD = 229 fg/mL), and displays an excellent performance profile in saliva (100.0% sensitivity, 100.0% specificity, 100.0% accuracy) and nasopharyngeal/oropharyngeal (88.7% sensitivity, 86.0% specificity, 87.4% accuracy) samples. Colorimetric RT-LAMP assay ( dos Santos et al, 2021 ) Saliva RNA The sensor had a LOD of 300 copies per reaction and showed a sensitivity of 80%, a specificity of 100%, a general accuracy of 99.59%, and a Cohen’s kappa of 0.887. LFIA immunosensor ( Roda et al, 2021 ) Serum, saliva IgA The LFIA immunosensor coupled with the smartphone reading enabled the one-step affordable determination of IgA levels in saliva.…”
mentioning
confidence: 99%