2018
DOI: 10.21577/0103-5053.20180124
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric Determination of Zn2+ in Antiseptic Dusting Powder and Multivitamins Using a Carbon Paste Electrode Modified with Bi Anchored on Amberlite® IR120

Abstract: This work presents a voltammetric method for Zn 2+ determination in antiseptic dusting powder and multivitamin commercial samples, combining an alkaline extraction using NaOH aqueous solution with a carbon paste electrode chemically modified with Bi anchored on Amberlite ® IR120 ion exchange resin (CPEAmb/Bi). The best conditions for electrode preparation were: 10% (m/m) of Amberlite ® IR 120; 30 s Bi 3+ accumulation time (open circuit) in 0.5 mmol L-1 Bi 3+ solution prepared in 0.1 mol L-1 acetate buffer (pH … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 31 publications
1
2
0
Order By: Relevance
“…Therefore, this composition was used in all the subsequent experiments. This result agrees with the literature, 6,34,35,54,55 which reports that CPEs with binder contents of 20-30% (m/m) are the most appropriate for electroanalytical applications. SEM images for PDMS and Nujol ® -CPEs are presented in Figure 2.…”
Section: Pdms-cpe Characterizationsupporting
confidence: 93%
See 2 more Smart Citations
“…Therefore, this composition was used in all the subsequent experiments. This result agrees with the literature, 6,34,35,54,55 which reports that CPEs with binder contents of 20-30% (m/m) are the most appropriate for electroanalytical applications. SEM images for PDMS and Nujol ® -CPEs are presented in Figure 2.…”
Section: Pdms-cpe Characterizationsupporting
confidence: 93%
“…The limit of detection (LOD) and the limit of quantification (LOQ) were estimated from the equations: LOD = 3 sd/b and LOQ = 10 sd/b, where b is the slope of the analytical curve and sd is the standard deviation for the signal of blank, which was estimated from the error of the intercept of the analytical curve. 6 For PDMS-CPE it was obtained LOD = 3 μmol L -1 and LOQ = 10 μmol L -1 , and Nujol ® -CPE provided LOD = 8 μmol L -1 and LOQ = 27 μmol L -1 . From Figure 8, it can be observed that the precision of the i p values obtained with the PDMS-CPE was superior to Nujol ® -CPE, which can be visualized by the larger error bars presented by Nujol ® -CPE.…”
Section: Pdms-cpe Characterizationmentioning
confidence: 90%
See 1 more Smart Citation