2015
DOI: 10.1590/s1516-8913201500371
|View full text |Cite
|
Sign up to set email alerts
|

Physicochemical and antioxidant properties of kiwifruit as a function of cultivar and fruit harvested month

Abstract: The present study was carried out to find the effect of fruit harvesting stage (October, November and December) on the physicochemical and antioxidant properties in five kiwi cultivars (Abbot, Bruno, Allison, Hayward, Monty). Results showed that soluble solid content (SSC) and pH increased while ascorbic acid (Vit C), titrated acidity (TAD) and SSC/TAD decreased in all the cultivars with delay in harvesting. Total polyphenols (TP) were decreased while total flavonoids (TF) increased in all tested

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
11
1
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 23 publications
4
11
1
2
Order By: Relevance
“…The TPC of fresh sample was 980.80 mg GAE/100 g d.w. This result is in accordance with literature (Pal et al, ). FD provided the highest TPC value in dried kiwifruit as expected (Izli et al, ; McSweeney & Seetharaman, ).…”
Section: Resultssupporting
confidence: 94%
“…The TPC of fresh sample was 980.80 mg GAE/100 g d.w. This result is in accordance with literature (Pal et al, ). FD provided the highest TPC value in dried kiwifruit as expected (Izli et al, ; McSweeney & Seetharaman, ).…”
Section: Resultssupporting
confidence: 94%
“…Content of soluble solids (Brix), refraction index (RI) and amount of NaCl was measured by applying four drops of clear extract onto a digital refractometer (Kern & Sohn Gmb ORF-3SM, Balingen, Germany). Content of soluble solids and amount of NaCl were expressed as a percentage [22].…”
Section: Refractometrymentioning
confidence: 99%
“…The load cell was equipped with a 3 mm diameter stainless steel (SS) probe, at a constant speed of 3 mm s -1 to a depth of 0.20 mm. The peak puncture force was treated as firmness of khoonphal and is measured in netwton (N) [21,22]. While the vitamin C content was assayed by titration method (2,6-dichlorophenolindophenol titration method).…”
Section: Firmness and Vitamin Cmentioning
confidence: 99%
“…While the vitamin C content was assayed by titration method (2,6-dichlorophenolindophenol titration method). The results of vitamin C were expressed as mg/100 g of FW [21].…”
Section: Firmness and Vitamin Cmentioning
confidence: 99%