2022
DOI: 10.1590/pboci.2022.063
|View full text |Cite
|
Sign up to set email alerts
|

Gingival Recession Treatment with the Use of Xenogeneic Matrix: Optimization of Patient-Centered Outcomes by the Digital Soft Tissue Design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
7
0
1

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(8 citation statements)
references
References 39 publications
0
7
0
1
Order By: Relevance
“…Parameter of recession depth (RecDep) defined as the distance between cementoenamel junction level and the position of free gingival margin in the projection of recession was measured both clinically and with the use of obtained intraoral scans. Clinical assessment of recession depth (RecDepClin) has been accomplished with the use of the North Carolina periodontal probe in millimeters (mm), while digital evaluation of recession depth (RecDepDig) was performed in 3Shape adapted software 3Shape Clear Aligners Studio (3Shape, Kyiv, Ukraine) [ 13 ]. The difference in clinical recession depth before and by the end of treatment (∆RecDepClin) has been calculated as the mathematical difference of RecDepClin parameter before and by the end of treatment, while the difference in digital recession depth before and by the end of treatment (∆RecDepDig) was measured after automatic intraoral scans superimposition within 3Shape adapted software using “Cross section” and “Measuring” instruments.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Parameter of recession depth (RecDep) defined as the distance between cementoenamel junction level and the position of free gingival margin in the projection of recession was measured both clinically and with the use of obtained intraoral scans. Clinical assessment of recession depth (RecDepClin) has been accomplished with the use of the North Carolina periodontal probe in millimeters (mm), while digital evaluation of recession depth (RecDepDig) was performed in 3Shape adapted software 3Shape Clear Aligners Studio (3Shape, Kyiv, Ukraine) [ 13 ]. The difference in clinical recession depth before and by the end of treatment (∆RecDepClin) has been calculated as the mathematical difference of RecDepClin parameter before and by the end of treatment, while the difference in digital recession depth before and by the end of treatment (∆RecDepDig) was measured after automatic intraoral scans superimposition within 3Shape adapted software using “Cross section” and “Measuring” instruments.…”
Section: Methodsmentioning
confidence: 99%
“…The parameter of mean root coverage deficiency (MRCD) was estimated based on the received digital scans by the end of orthodontic treatment as a difference between potential full soft tissue coverage to cemento-enamel junction (CEJ) level as a reference line and resulted soft tissue coverage of the root surface in the area of recession, represented in percentage (%) [ 13 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Сучасні тенденції стоматологічного лікування асоційовані із вищим рівнем пацієнт-орієнтованості втручань та мінімізацією обсягу ятрогенної травми без компрометації майбутнього прогнозу реабілітації [1; 2]. У пародонтологічній практиці реалізація даних принципів забезпечується шляхом оптимізації класичних оперативних маніпуляцій через модифікацію технік виконання розрізів, формування клаптів та застосування різних видів трансплантатів [1][2][3][4][5].…”
unclassified