2007
DOI: 10.1590/s1678-77572007000200015
|View full text |Cite
|
Sign up to set email alerts
|

Fracture of abutment screw supporting a cemented implant-retained prosthesis with external hexagon connection: a case report with sem evaluation

Abstract: One of the causes of implant failures in cemented implant-retained prostheses is the fracture of abutment screw or UCLA abutment. This article reports a case of simultaneous fracture of two UCLA abutments screws occurring in an implant-supported prosthesis placed in the mandibular molar region. The fractured structures were examined under scanning electron microscopy to investigate the probable causes of the failure, which were not related to failures on materials or fabrication of the screws, but rather were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0
2

Year Published

2012
2012
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 3 publications
0
11
0
2
Order By: Relevance
“…9,14 The absence of passivity between components has also been shown to increase stress in the screw and results in metal fatigue failure and screw loosening. 17,18 Narrow-diameter implants (3.0 to 3.4 mm) were recently developed. 17,18 Narrow-diameter implants (3.0 to 3.4 mm) were recently developed.…”
Section: Introductionmentioning
confidence: 99%
“…9,14 The absence of passivity between components has also been shown to increase stress in the screw and results in metal fatigue failure and screw loosening. 17,18 Narrow-diameter implants (3.0 to 3.4 mm) were recently developed. 17,18 Narrow-diameter implants (3.0 to 3.4 mm) were recently developed.…”
Section: Introductionmentioning
confidence: 99%
“…De acordo com Santos et al 8 , o modelo e material utilizados na confecção dos componentes implantossuportados influenciam claramente nos processos de deformação plástica, desgaste ou falha das peças protéticas. No presente estudo, não houve essa relação entre modelo, material e falhas, já que os tipos de pilares testados são do mesmo material e comportaram-se de maneira semelhante no que diz respeito à resistência às cargas e ao local de fratura dos implantes, apesar de possuírem modelos diferentes.…”
Section: Discussionunclassified
“…Adicionalmente, a má adequação do quadro clínico, como a presença de desajuste oclusal, conduzindo à fadiga do material, e falhas intrínsecas dos componentes, como defeitos de usinagem, podem estar relacionadas à fratura desses elementos 7,8 .…”
Section: Introductionunclassified
“…11,12 Abutment screw fractures are associated with inadequate screw tightening, screw loosening, improper occlusion concept, premature occlusal contacts, parafunctional habits, cervical misfit of the prosthesis and consequent fatigue of the screw material, fatigue character and yielding strength of the screw material, and fabrication failures. 4,6,11,13,14 Fractured abutment screws may be replaced by new abutment screws. However, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced.…”
Section: Introductionmentioning
confidence: 99%
“…However, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. 13,14 The physical properties and the design of screws and restorative components dictate their fracture strength and failure mode. 7 Abutment screws can be made from a variety of materials.…”
Section: Introductionmentioning
confidence: 99%