Removal of intramural trapped intrauterine device by cystoscopic incision of bladder wall

Abstract: A healthy 37 - year - old woman referred to our clinic with one - year history of recurrent urinary tract infection, dysuria and frequency. Her past medical history informed us that an IUD (Copper TCu380A) had been inserted 11 years ago. Eleven months after the IUD insertion she had become pregnant, unexpectedly. At that time, she had undergone gynecological examination and abdominal ultrasound study. However, the IUD had not been found, and the gynecologist had made the diagnosis of spontaneous fall out of th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 2 publications
(2 reference statements)
0
5
0
Order By: Relevance
“…However, unless the extraction is performed by experienced hands, the risk of urine leak and uterovesical fistula can be significant. 1,3,8,17 In our patient, a trial of cystoscopic removal was unsuccessful due to tight local adhesion, and hence an open trans-vesical removal was performed.…”
Section: Dovepressmentioning
confidence: 85%
See 4 more Smart Citations
“…However, unless the extraction is performed by experienced hands, the risk of urine leak and uterovesical fistula can be significant. 1,3,8,17 In our patient, a trial of cystoscopic removal was unsuccessful due to tight local adhesion, and hence an open trans-vesical removal was performed.…”
Section: Dovepressmentioning
confidence: 85%
“…In such cases, a contrast-enhanced CT scan is recommended to define the device orientation and possible local attachment. 1 , 16 , 17 …”
Section: Discussionmentioning