2008
DOI: 10.1590/s1415-54192008000500012
|View full text |Cite
|
Sign up to set email alerts
|

Grau de aceitação de mini-implantes por pacientes em tratamento ortodôntico: estudo preliminar

Abstract: OBJETIVOS: os mini-implantes atualmente representam um grande avanço na Ortodontia, por proporcionarem máxima ancoragem com o mínimo de cooperação dos pacientes. No entanto, ainda existem algumas dúvidas quanto ao uso destes dispositivos temporários de ancoragem no que se refere, principalmente, aos aspectos psicológicos de aceitação pelos pacientes durante o tratamento ortodôntico. METODOLOGIA: dez pacientes adultos, portadores de má oclusão de Classe I, com biprotrusão, que foram submetidos a tratamento orto… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(13 citation statements)
references
References 11 publications
0
13
0
Order By: Relevance
“…During the insertion, control features should be used such as micro-motor with controlled torque, 13 manual wrench 1 or dynanometer 27 to prevent this torque from approaching or reaching the fracture torque of mini-implants. Fracture toughness of mini-implants varies according to the manufacturer and type of mini-implant, so the operator should be aware of the characteristics of mini-implants that influence the torque values of fracture before choosing one to be used, and the maximum torque that can safely be used clinically for the insertion 18 …”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…During the insertion, control features should be used such as micro-motor with controlled torque, 13 manual wrench 1 or dynanometer 27 to prevent this torque from approaching or reaching the fracture torque of mini-implants. Fracture toughness of mini-implants varies according to the manufacturer and type of mini-implant, so the operator should be aware of the characteristics of mini-implants that influence the torque values of fracture before choosing one to be used, and the maximum torque that can safely be used clinically for the insertion 18 …”
Section: Discussionmentioning
confidence: 99%
“…Mini-implants have been an effective anchorage method, 1 being very well tolerated by patients, 2 creating new possibilities for orthodontic treatment that requires minimal cooperation and maximum aesthetics results, particularly in adults 3 . Unlike osseointegrated dental implants made of commercially pure titanium, mini-implants are manufactured with the alloy Ti6Al4V (ASTM grade 5) 4 …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…All patients presented the germen of the maxillary third molars and the maxillary second molars erupted at the beginning of treatment. Four 11.0 to 14.7 years) obtained from the files of the same Orthodontic Department, who did not receive any orthodontic treatment. The control group was an untreated historical control group selected in order to match the experimental group, according to the inclusion criteria.…”
Section: Materials and Methods Materialsmentioning
confidence: 99%
“…However, these devices cannot be used in all cases, for several factors as failure of the miniscrews, no patient acceptance due to surgical procedure necessary to installation, or by the presence of systemic disorder. [8][9][10][11] In these cases, the orthodontist should use intraoral distalizer with conventional anchorage.…”
Section: Introductionmentioning
confidence: 99%