2011
DOI: 10.1590/s1413-41522011000400004
|View full text |Cite
|
Sign up to set email alerts
|

Desinfecção de água de chuva por radiação ultravioleta

Abstract: ResumoO objetivo deste trabalho foi avaliar o tratamento de água de chuva, de duas regiões industriais de Joinville (SC), por radiação ultravioleta. O reator operou em processo contínuo, de modo que cada partícula permanecesse sob radiação por 60 segundos. As amostras de água foram analisadas em termos de coliformes totais, coliformes termotolerantes e bactérias heterotróficas antes do tratamento por ultravioleta, após o tratamento e após tratadas e armazenadas por 24, 48 e 72 horas. Verificou-se a eficiência … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
3
0
2

Year Published

2017
2017
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 6 publications
0
3
0
2
Order By: Relevance
“…Ultraviolet band C (UVC -254 nm) is used as germicide. However, in sublethal doses, microorganisms can recover their metabolic activity, in addition to requiring a physical barrier to protect the operator due to its carcinogenic potential (Wisbeck et al, 2011;Di-Bernardo et al, 2017;Mbonimpa et al, 2018).…”
Section: Introductionmentioning
confidence: 99%
“…Ultraviolet band C (UVC -254 nm) is used as germicide. However, in sublethal doses, microorganisms can recover their metabolic activity, in addition to requiring a physical barrier to protect the operator due to its carcinogenic potential (Wisbeck et al, 2011;Di-Bernardo et al, 2017;Mbonimpa et al, 2018).…”
Section: Introductionmentioning
confidence: 99%
“…This observation is of great relevance and validates the effectiveness of the reactor used due the possibility of enzymatic photoreactivation. Wisbeck et al (2011), evaluated the treatment of rainwater by ultraviolet radiation, analyzing total coliforms, tolerant coliforms and heterotrophic bacteria before, after and then after being translated and stored for 24, 48 and 72 hours. With a 30 W lamp and a flow rate of 0.04 s -1 , it achieved 100% effectiveness in the inactivation of total and fecal coliforms for up to 72 hours, unlike the heterotrophic bacteria that identified in the 3 storage times after treatment.…”
Section: Resultsmentioning
confidence: 99%
“…El agua lluvia puede convertirse en una fuente de agua no convencional, debido a que no existe una vinculación directa con otro tipo de suministro de agua potable. A pesar de ello, el agua lluvia puede considerarse de buena calidad, siempre y cuando se tengan los cuidados necesarios durante su captación y almacenamiento [9].…”
Section: Introductionunclassified