2008
DOI: 10.1590/s0482-50042008000200004
|View full text |Cite
|
Sign up to set email alerts
|

Estudo da macrovasculatura por ultra-sonografia Doppler na esclerose sistêmica

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
1
1

Year Published

2012
2012
2013
2013

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 21 publications
1
1
1
Order By: Relevance
“…On Figures 2 and 4, it is possible to observe that all the measurements remain grouped at a single level, with the exception of the measurement at the origin of the right subclavian artery. As a variation < 0.1 mm is adopted as a reference for the acceptance of a clinical threshold of agreement (23)(24)(25)(26) , one observes, in the present study, that the only clinically significant difference was the measurement at the origin of the right subclavian artery. For such result, all comparisons between automatic and manual measurements in the HIV patients and control groups were taken into consideration, adopting the mean automatic measurement on the RCC as a standard.…”
Section: Discussionsupporting
confidence: 55%
See 1 more Smart Citation
“…On Figures 2 and 4, it is possible to observe that all the measurements remain grouped at a single level, with the exception of the measurement at the origin of the right subclavian artery. As a variation < 0.1 mm is adopted as a reference for the acceptance of a clinical threshold of agreement (23)(24)(25)(26) , one observes, in the present study, that the only clinically significant difference was the measurement at the origin of the right subclavian artery. For such result, all comparisons between automatic and manual measurements in the HIV patients and control groups were taken into consideration, adopting the mean automatic measurement on the RCC as a standard.…”
Section: Discussionsupporting
confidence: 55%
“…In the comparison between measurements on LCC in HIV patients and control groups, as shown on Figures 3 and 5, it is possible to observe that the mean automatic measurement value was closer to the minimum manual measurement value and more distant from the maximum manual measurement value, but, considering the variation of < 0.1 mm (23)(24)(25)(26) , there was no clinical relevance in such a variation in the present study.…”
Section: Discussioncontrasting
confidence: 45%
“…The ankle-brachial index (ABI) is a non-invasive method with high predictive value for peripheral arterial disease, and it is significantly associated with the risk of cardiovascular mortality; its cost is low, and it has been validated in the general population 15,33 . Reduction of ABI to values lower than 0.9 is associated with the significant increase in cardiovascular risk, especially by AMI and stroke, independently of other risk factors 34,35 .…”
Section: Introductionmentioning
confidence: 99%