Desenvolvimento de um sistema de fachada ventilada com placas cerâmicas de grês porcelanato voltado para a construção civil do Brasil

Abstract: No presente estudo buscou-se desenvolver e analisar um protótipo de sistema de fixação de placas cerâmicas de grês porcelanato em fachada ventilada a partir de tecnologia existente no país. Além disso, procurou-se analisar aspectos como os efeitos da operação de execução de furos no material cerâmico, além de propriedades relacionadas com a interação das placas cerâmicas com parafusos expansores para fixação, como torque máximo no aperto destes parafusos e resistência da união entre parafusos e placas. Desta f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 0 publications
0
7
0
1
Order By: Relevance
“…The error made on this percentage is about 5%-10%.The mineral phase 18516: Teil 1 standard establishes general considerations regarding the project, acting loads, volumetric variations, the execution of the ventilated façade system, and performance tests. 4 The basic NBE-CT-79 6 standard on thermal conditions in buildings describes in detail the calculation of conductivity in ventilated chamber rooms, as well as aspects related to the thermal conditions of buildings. The Italian standard UNI 11018: 2003 7 states that the ventilated façade is a type of advanced barrier façade.…”
Section: Methods Of Characterizationmentioning
confidence: 99%
See 2 more Smart Citations
“…The error made on this percentage is about 5%-10%.The mineral phase 18516: Teil 1 standard establishes general considerations regarding the project, acting loads, volumetric variations, the execution of the ventilated façade system, and performance tests. 4 The basic NBE-CT-79 6 standard on thermal conditions in buildings describes in detail the calculation of conductivity in ventilated chamber rooms, as well as aspects related to the thermal conditions of buildings. The Italian standard UNI 11018: 2003 7 states that the ventilated façade is a type of advanced barrier façade.…”
Section: Methods Of Characterizationmentioning
confidence: 99%
“…The chemical composition of basalt and lime mud was determined by X-ray fluorescence (XRF, Panalytical, model WRFDX AXIOS MAX). The crystalline phases were identified by X-ray diffraction (XRD, Phillips, X'Pert MDP model; CuKα radiation, 2θ range of 5° to 75°, speed of 0.05°/s, slits behavior and the ceramic propert larly in the Sejnène region, northw the chemical composition, these c terized by high iron contents who of the ceramic materials is well k of fluxing agents as alkali and alk are necessary for low temperatur considered materials consist entir containing impurities, mostly ill iron, which serve as fluxing agen at low temperature [3][4][5][6] and appeare physical and mechanical propertie ramic materials.…”
Section: Characterization Of Basalt and Lime Mudmentioning
confidence: 99%
See 1 more Smart Citation
“…As fachadas ventiladas buscam ocupar um papel importante, não só por seu potencial estético e impacto visual na construção civil, mas sim por seu potencial técnico para contribuição de uma forma decisiva no desempenho térmico e estrutural do conjunto arquitetônico da obra. Para este sistema, podem ser empregados diversos materiais, tais como as placas cerâmicas e as placas de pedras naturais, normalmente em grandes formatos [1]. Habitualmente no mercado são especificados revestimentos cerâmicos (porcelanato) com absorção de água nula ou quase nula.…”
Section: Introductionunclassified
“…Porcelain tiles are an attractive material for application as ventilated façade due to their highlighted technical properties as low water absorption (<0.5%), 19 high rupture load (≥1000 N), high bending strength (≥45 MPa), high resistance to deep abrasion (≤140 mm 3 ), high ice resistance, acid and alkali resistance, color uniformity, and impermeability 20…”
Section: Introductionmentioning
confidence: 99%