2012
DOI: 10.1590/s0103-50532012000100014
|View full text |Cite
|
Sign up to set email alerts
|

HPCL determination of histamine, tyramine and amino acids in shrimp by-products

Abstract: Aminas biogênicas em alta concentração podem afetar a qualidade dos alimentos e causar várias doenças, pois estão presentes em produtos como frutos do mar, vinhos e outros produtos fermentados. Subprodutos do camarão são uma fonte rica de proteína hidrolisada que podem ser usadas como suplemento alimentar. Amostras (de subprodutos de camarão) de proteína seca em pó, proteínas hidrolisadas líquidas e farinha da cabeça de camarão foram analisadas para avaliar o conteúdo de histamina e tiramina. As aminas foram e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…The developed UPLC method had lower deviations on repeatability and reproducibility in determining tyramine in different types of food products (Table ). The repeatability of using a HPLC method to determine the tyramine in shrimp products was in a range of 1.65–6.55%, while it was from 2.2% to 14.8% for the fermented fish sauces (Bueno‐Solano et al ., ; Jiang et al ., ). The deviations of the repeatability and reproducibility for soy sauce were reported from 0.65% to 6.40% and from 0.97% to 9.20% (Guidi & Gloria, ).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The developed UPLC method had lower deviations on repeatability and reproducibility in determining tyramine in different types of food products (Table ). The repeatability of using a HPLC method to determine the tyramine in shrimp products was in a range of 1.65–6.55%, while it was from 2.2% to 14.8% for the fermented fish sauces (Bueno‐Solano et al ., ; Jiang et al ., ). The deviations of the repeatability and reproducibility for soy sauce were reported from 0.65% to 6.40% and from 0.97% to 9.20% (Guidi & Gloria, ).…”
Section: Discussionmentioning
confidence: 99%
“…The range of the recoveries in this study was similar to most previous studies (Table ). For example, the ranges of recoveries were from 86.1% to 114.4% for fermented fish sauces, 84.1% to 95.6% for fish products, 84.29% to 98.68% for shrimp by‐products and 86.4% to 112% for wines (Park et al ., ; Bueno‐Solano et al ., ; Jiang et al ., ). For the cheese sample, it was reported in a range of 63.3–140.0% (Redruello et al ., ).…”
Section: Discussionmentioning
confidence: 99%
“…Histamine testing was carried out by referring to the method of [63] with slight modifications. A sample (5 g) was placed in a 25-mL volumetric flask, diluted with 5% of TCA, homogenized, sonicated (15 min), and replaced in a 2-mL Falcon tube and centrifuged at 14,000 rpm for 3 min.…”
Section: Quality Determination Of Fish Skin As a Source Of Collagenmentioning
confidence: 99%
“…2006;Simo et al 2008;Nevado Berzas et al 2011), gas chromatography (Cunha et al 2011;Yoshida et al 2012;Hwang et al 2003), thin-layer chromatography (Romano et al 2012;Bozina et al 1999) and high-pressure liquid chromatography (Bueno-Solano et al 2012;Yoshitake et al 2012;Kose et al 2011) using different kinds of detection.…”
Section: Introductionmentioning
confidence: 99%