2011
DOI: 10.1590/s0103-50532011000700008
|View full text |Cite
|
Sign up to set email alerts
|

Determination of etimicin in rat plasma using 9-fluorenylmethyl chloroformate precolumn derivatization by HPLC with fluorescence detection

Abstract: Um método novo e sensível foi desenvolvido para a determinação de etimicina (ETM) utilizando pré-coluna de derivatização (PCD) com 9-fluorenilmetilcloroformiato (FMOC-Cl) por separação de fase reversa e subsequente detecção por fluorescência. As condições PCD foram todas otimizadas para o menor limite de detecção. A separação cromatográfica foi efetuada em uma coluna Agilent XDB-C8 a 25 o C, velocidade de fluxo de 1,0 mL min -1 e fase móvel acetonitrila/água (87:13, v/v). O derivativo etimicina-FMOC-Cl foi mon… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2015
2015

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…mL -1 [85]. Similar FMOC-Cl derivatization and detection was performed for the determination etimicin in rat plasma using an RP C8 column [52].…”
Section: Pre-column Derivatizationmentioning
confidence: 99%
“…mL -1 [85]. Similar FMOC-Cl derivatization and detection was performed for the determination etimicin in rat plasma using an RP C8 column [52].…”
Section: Pre-column Derivatizationmentioning
confidence: 99%
“…For single group, they were decided according to the guidance for preclinical pharmacokinetics and some reported references [20,21]. As for the combined group, we took both the time points for the two analytes and different start times of each analyte into consideration.…”
Section: Way Of Intravenous Administration Of Analytes To Beagle Dogsmentioning
confidence: 99%
“…For the determination of etimicin for pharmacokinetics, most of them were carried out by bioassay methods [6]. A new chromatographic method of precolumn derivatization with HPLC and fluorescence detection for determination of etimicin in rat plasma was reported recently, which was sensitive but the sample pre-treatment procedures were technically demanding and time consuming [21]. Some LC-MS/MS methods were developed for the impurity profiling of etimicin sulfate or determination of etimicin in some biological samples [22,23], but none of them was deal with the pharmacokinetic application.…”
Section: Introductionmentioning
confidence: 99%