2009
DOI: 10.1590/s0103-50532009000800021
|View full text |Cite
|
Sign up to set email alerts
|

Micelle-mediated extraction and determination of tin in soft drink and water samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
13
0
2

Year Published

2011
2011
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(15 citation statements)
references
References 16 publications
(17 reference statements)
0
13
0
2
Order By: Relevance
“…Unlike these techniques, Ultraviolet-visible (UV-vis) spectroscopy is a simple instrument, cheap, easy operated, rapid response time, available in many laboratories. But, the CPE was efficiently coupled with spectrophotometry and spectrofluorometry, and successfully used in order to increase its low detection limit as well as the selectivity of the technique (Gurkan and altunay 2013;Jamshid et al 2006;Madrakian and Ghazizadeh 2009). …”
Section: Introductionmentioning
confidence: 99%
“…Unlike these techniques, Ultraviolet-visible (UV-vis) spectroscopy is a simple instrument, cheap, easy operated, rapid response time, available in many laboratories. But, the CPE was efficiently coupled with spectrophotometry and spectrofluorometry, and successfully used in order to increase its low detection limit as well as the selectivity of the technique (Gurkan and altunay 2013;Jamshid et al 2006;Madrakian and Ghazizadeh 2009). …”
Section: Introductionmentioning
confidence: 99%
“…In contrast spectrophotometric methods are preferred due to their simplicity and speed in routine analysis. The reported studies have shown that a large number of reagents such as methyl orange [11], benzopyran derivatives [1,12,13], 2-(5-nitro-2-pyrilazo)-5-[N-n-propyl-N-(3-sulfopropyl)amino-phenoyl] [14], pyrocatechol violet [15][16][17][18], phenylfluorone [19,20], dibromohydroxyphenylfluorone [21], arsenazo-M [22], isoamyl xanthate [23], diacetylmonoxime-p-hydroxybenzoyl-hydrazine [24], bromopyrogallol red [25], potassium ethylxanthate [26], ferron [27], and 5,7-dichloro-8-quinolinol [28] have been used for the spectrophotometric determination of tin(II,IV) content. Among these many reagents [18,21,23,[26][27][28] are nonselective as they suffer from the interference, have low sensitivity [11,12,23,24,[26][27][28], and some of them are time consuming, as they require time for full color development [14,18,20].…”
Section: Introductionmentioning
confidence: 99%
“…Among these many reagents [18,21,23,[26][27][28] are nonselective as they suffer from the interference, have low sensitivity [11,12,23,24,[26][27][28], and some of them are time consuming, as they require time for full color development [14,18,20]. Some of the sensitive reagents [16,17,21,22,25] are reported, but these require the use of the surfactants, plasticizer, and critical pH adjustment. Thus in the view of the above facts it reveals that there is still a lot of scope for working out new methods and effecting amendments in the existing ones especially because of their lower sensitivity and selectivity.…”
Section: Introductionmentioning
confidence: 99%
“…[23][24][25][26] For metal determination, a reaction with a hydrophobic complexing agent is usually required. 27 The hydrophobic complex is then extracted into micelles of a non-ionic surfactant, such as Triton X-114, and separated from the aqueous phase.…”
mentioning
confidence: 99%
“…) was used as the extracting agent in view of the highly convenient cloud point formation (23)(24)(25) C).…”
mentioning
confidence: 99%