2007
DOI: 10.1590/s0103-50532007000300004
|View full text |Cite
|
Sign up to set email alerts
|

A chemiluminescence flow-based procedure for determination of carbaryl in natural waters exploiting multicommutation and enzymatic reaction

Abstract: Um procedimento empregando detecção quiluminescente para determinação de carbaril em águas naturais utilizando acetilcolinesterase e colina oxidase é descrito. O módulo de análise projetado para implementar o processo de multicomutação controlado por microcomputador foi constituído por cinco válvulas solenóides, duas colunas com enzimas imobilizadas em esferas de vidro e cela de fluxo para detecção de quimiluminescência. Nas melhores condições experimentais foi obtida faixa linear entre 25 a 700 μg L -1 de car… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…In the SIA approach, the solution propelling has been carried out using a single pumping channel (Santos and Masini 2007;Abate et al 2006;, thus allowing the use of an automatic syringe (Santos et al 2005b) or a peristaltic pump ). In the MCFIA approach, the peristaltic pump is the most used device for solutions propelling Pires et al 2007; Garcia and Reis 2006;Maruchi and Rocha 2006;Vieira et al 2006;Rodenas-Torralba et al 2005). Recently, the solenoid micro-pump has been introduced as an alternative to peristaltic pump (Lapa et al 2002;Rocha et al 2005;Santos and Masini 2007;Ribeiro et al 2007;Santos and Masini 2007;Carneiro et al 2005), presenting, as advantages, small size and commuting features, and thus permitting its use to replace both peristaltic pump and solenoid valve.…”
Section: Brief Historymentioning
confidence: 99%
“…In the SIA approach, the solution propelling has been carried out using a single pumping channel (Santos and Masini 2007;Abate et al 2006;, thus allowing the use of an automatic syringe (Santos et al 2005b) or a peristaltic pump ). In the MCFIA approach, the peristaltic pump is the most used device for solutions propelling Pires et al 2007; Garcia and Reis 2006;Maruchi and Rocha 2006;Vieira et al 2006;Rodenas-Torralba et al 2005). Recently, the solenoid micro-pump has been introduced as an alternative to peristaltic pump (Lapa et al 2002;Rocha et al 2005;Santos and Masini 2007;Ribeiro et al 2007;Santos and Masini 2007;Carneiro et al 2005), presenting, as advantages, small size and commuting features, and thus permitting its use to replace both peristaltic pump and solenoid valve.…”
Section: Brief Historymentioning
confidence: 99%
“…A chemiluminescence flow-based method for determination of carbaryl in natural waters utilizing multicommutation and enzymatic reaction was reported (Pires et al, 2007). Acetylcholinesterase and choline oxidase were used for the enzymatic reaction.…”
mentioning
confidence: 99%