2007
DOI: 10.1590/s0103-50532007000200016
|View full text |Cite
|
Sign up to set email alerts
|

Application of pyridine-2-carbaldehyde-2-(4-methyl-1,3-benzo thiazol-2-yl)hydrazone as a neutral ionophore in the construction of a novel Er(III) sensor

Abstract: A piridina-2-carbaldeído-2-(4-metil-1,3-benzotiazol-2-il) hidrazona (PCMHT) pode ser usada como um ionóforo neutro apropriado à preparação de uma membrana sensora a Er(III), com alta seletividade. A composição ótima encontrada foi PCMHT-PVC-KTpClPB-BA com as razões de 6,0:30,0:5,0:59,0 . A excelente seletividade a Er(III) do sensor proposto, frente aos íons metálicos mais comuns e, especialmente íons lantanídeos, é uma outra vantagem. O sensor foi usado com sucesso como eletrodo indicador na titulação de 25 m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 20 publications
(35 reference statements)
0
7
0
Order By: Relevance
“…19.1 ± 0.3 7.6 × 10 −8 10 18.9 ± 0.3 7.5 × 10 −8 11 18.7 ± 0.5 7.8 × 10 −8 12 18.8 ± 0.3 7.9 × 10 −8 13 17.9 ± 0.2 1.5 × 10 −7 14 17.8 ± 0.3 1.9 × 10 −7 15 17.6 ± 0.3 2.5 × 10 −7 3.8. Tempreature effect on potential response of the sensor Fig.…”
Section: Lifetimementioning
confidence: 99%
See 1 more Smart Citation
“…19.1 ± 0.3 7.6 × 10 −8 10 18.9 ± 0.3 7.5 × 10 −8 11 18.7 ± 0.5 7.8 × 10 −8 12 18.8 ± 0.3 7.9 × 10 −8 13 17.9 ± 0.2 1.5 × 10 −7 14 17.8 ± 0.3 1.9 × 10 −7 15 17.6 ± 0.3 2.5 × 10 −7 3.8. Tempreature effect on potential response of the sensor Fig.…”
Section: Lifetimementioning
confidence: 99%
“…A survey of the literature found only four reports on Er(III) ion-selective and wire coated sensors [13][14][15][16], and no reports of Er(III) carbon paste electrodes. In this work, for the first time, a highly selective and sensitive Er(III) modified carbon paste electrode based on [5-(dimethylamino) naphthalene-1-sulfonyl 4-phenylsemicarbazide] (NSP), room temperature ionic liquids (RTILs) and multi-walled carbon nanotubes (MWCNTs) is studied (Fig.…”
Section: Introductionmentioning
confidence: 99%
“…(Xia et al, 2005). Pyridine derivatives can be used as a suitable neutral ionophore for preparing an Er(III) membrane sensor with high selectivity, which are utilized for direct monitoring of Er(III) in binary mixtures and indirect determination of fluoride ions in mouth wash preparations (Ganjali et al, 2007).…”
Section: Data Collectionmentioning
confidence: 99%
“…One in 2006 by Ganjali et al, who created an Er 3+ hydrazone based sensor, presenting a detection limit of 7.0 10 8 M [85]. The other one in 2007 by Ganjali et al, who found that pyridine-2-carbaldehyde-2-(4-methyl-1,3-benzothiazol-2-yl) hydrazone (PCMHT) could be used as a suitable neutral ionophore [86]. Table 3 is thulium.…”
Section: Lanthanide Metalsmentioning
confidence: 99%