2006
DOI: 10.1590/s0103-50532006000700015
|View full text |Cite
|
Sign up to set email alerts
|

Construction of a novel potentiometric terbium(III) membrane sensor and its application for the determination of terbium ion in binary mixture and fluoride ion in a mouth wash preparation

Abstract: Um novo sensor potenciométrico constituído por uma membrana de PVC, altamente seletivo a íons Tb(III) foi preparado usando-se 4-amino-3-{2-[4-amino-6-metil-5-oxo-4,5-diidro-1,2,4triazina-3(2H)-ilidina] hidrazono}-6-metil-3,4-diidro-1,2,4-triazina-5(2H)-ona (ATO) como um carregador adequado. O sensor trabalha satisfatoriamente no intervalo de concentração de 1,0 × 10 -6 a 1,0 × 10 -1 mol L -1 (limite de detecção 8,6 × 10 -7 mol L -1 ) com uma inclinação Nernstiniana de 19,4 ± 0.5 mV per década de atividade. O e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 23 publications
(16 citation statements)
references
References 12 publications
(15 reference statements)
0
16
0
Order By: Relevance
“…Other sensors include Eu 3+ [171,172], Gd 3+ [173][174][175][176], Tb 3+ [177,178], Dy 3+ [179,180], Ho 3+ [181,182], Er 3+ [183], Tm 3+ [184,185], Yb 3+ [186][187][188] PMEs, in addition to one Lu 3+ PME [189] and two uranyl PMEs and GCE [190,191]. The minimum detection limit among all of these sensors is reported to be 7.0 × 10 -8 for uranyl ion [191], which is a 2,2'- …”
Section: Cation Selective Sensorsmentioning
confidence: 99%
“…Other sensors include Eu 3+ [171,172], Gd 3+ [173][174][175][176], Tb 3+ [177,178], Dy 3+ [179,180], Ho 3+ [181,182], Er 3+ [183], Tm 3+ [184,185], Yb 3+ [186][187][188] PMEs, in addition to one Lu 3+ PME [189] and two uranyl PMEs and GCE [190,191]. The minimum detection limit among all of these sensors is reported to be 7.0 × 10 -8 for uranyl ion [191], which is a 2,2'- …”
Section: Cation Selective Sensorsmentioning
confidence: 99%
“…Thus, the development of new ion-selective electrodes for lanthanides is still a challenging task. A number of investigations into the development of terbiumselective electrodes using bispyrr olidene schiff's base [26], 4-amino-3-{2-[4-amino-6methyl-5-oxo-4,5-dihydro-1,2,4-triazin-3-(2H)-yliden]hydrazono}-6-methyl-3,4-dihydro-1,2,4-triazin-5(2H)-one [27] and S-2-benzothiazo lyl-2-amino-␣-(methoxyimino)-4-thiazolethiol acetate [28] have been reported in the literature but they have a narrow dynamic range and high detection limit.…”
Section: Introductionmentioning
confidence: 99%
“…[12][13][14][15][16][17][18] Recently, several greatly selective and sensitive PVC-membrane ionselective electrodes for various metal ions have been reported. [19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36][37] Nevertheless, this paper focuses on the introduction of a highly siver(I)-selective sensor based on Dilaktam Crown ether (DLCE) (Fig. 1), as a novel neutral ionophore for monitoring silver concentration.…”
Section: Introductionmentioning
confidence: 99%