2005
DOI: 10.1590/s0103-50532005000600007
|View full text |Cite
|
Sign up to set email alerts
|

Flow system for pre-concentration and spectrophotometric determination of reactive mercury

Abstract: Um novo sistema em fluxo é apresentado com a finalidade de pré-concentrar e determinar o mercúrio reativo em efluentes. O sistema é baseado na redução do mercúrio reativo presente em 500 mL de amostra com uma solução de Sn(II). O mercúrio reduzido é arrastado por uma corrente de argônio que passa por um tubo de vidro (comprimento de 60 cm, e diâmetro interno de 3 mm) inclinado a 15º. A superfície interna desse tubo é recoberta previamente com um filme líquido de uma solução oxidante contendo ; pH 9,0) é introd… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2010
2010
2012
2012

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 24 publications
0
2
0
Order By: Relevance
“…[6][7][8][9] Its narrow emission band (l = 25 nm) has enabled it to be used without a monochromator system, thus simplifying the photometer design. [10][11][12] Multicommuted flow analysis process affords facilities to design active flow setup constituted by solenoid valves, which have been assembled to work as an independent commutator unit, thus allowing facilities to handle sample and reagent solutions controlled by microcomputer. [8][9][10][11]13,14 Zinc is present in all living cells as a constituent of several molecules involved in proteins, lipids and carbohydrates metabolism, as well as several enzymes.…”
Section: Introductionmentioning
confidence: 99%
“…[6][7][8][9] Its narrow emission band (l = 25 nm) has enabled it to be used without a monochromator system, thus simplifying the photometer design. [10][11][12] Multicommuted flow analysis process affords facilities to design active flow setup constituted by solenoid valves, which have been assembled to work as an independent commutator unit, thus allowing facilities to handle sample and reagent solutions controlled by microcomputer. [8][9][10][11]13,14 Zinc is present in all living cells as a constituent of several molecules involved in proteins, lipids and carbohydrates metabolism, as well as several enzymes.…”
Section: Introductionmentioning
confidence: 99%
“…[3][4][5][6] Small size, low cost, high stability of the radiation beam, and long lifetime are the main features of LEDs which explains its widespread use in different analytical procedures. [7][8][9] The availability of LEDs with wavelengths ranging from ultraviolet (l ca. 380 nm) to near infrared (l ca.…”
Section: Introductionmentioning
confidence: 99%