Studies on the stability of anodic oxides on zirconium biocompatible alloys

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
23
0

Year Published

2005
2005
2017
2017

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(26 citation statements)
references
References 20 publications
3
23
0
Order By: Relevance
“…Zirconium has acceptable mechanical strength and good biocompatibility. 14,15 Zirconium implants exhibit good osseointegration and the degree of bone-implant contact is higher for Zr than for Ti. [16][17][18][19] Only few alloys with zirconium were elaborated for implant use: Ti-2.2Al-2.6Zr, 11 Ti-13Nb-13Zr, 20,21 Ti-15Zr-4Nb-4Ta, 10 Ti-15Zr-4Nb-4Ta-0.2Pd, 22 Ti-50Zr and Zr-25Nb.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Zirconium has acceptable mechanical strength and good biocompatibility. 14,15 Zirconium implants exhibit good osseointegration and the degree of bone-implant contact is higher for Zr than for Ti. [16][17][18][19] Only few alloys with zirconium were elaborated for implant use: Ti-2.2Al-2.6Zr, 11 Ti-13Nb-13Zr, 20,21 Ti-15Zr-4Nb-4Ta, 10 Ti-15Zr-4Nb-4Ta-0.2Pd, 22 Ti-50Zr and Zr-25Nb.…”
Section: Introductionmentioning
confidence: 99%
“…[16][17][18][19] Only few alloys with zirconium were elaborated for implant use: Ti-2.2Al-2.6Zr, 11 Ti-13Nb-13Zr, 20,21 Ti-15Zr-4Nb-4Ta, 10 Ti-15Zr-4Nb-4Ta-0.2Pd, 22 Ti-50Zr and Zr-25Nb. 14 The new Romanian Ti-6Al-4V-1Zr alloy was elaborated for to combine the very good mechanical properties of Ti-6Al-4V alloy with the good biocompatibility of zirconium. Its corrosion resistance in Ringer-Brown solution and Carter-Brugirard artificial saliva of different pH values was studied in this paper.…”
Section: Introductionmentioning
confidence: 99%
“…The electrochemical method used to grow the oxide films consisted of a linear potential scan (v D 50 mV/s) from a potential in the hydrogen evolution region ( 1.6 V vs SCE) towards more positive potentials (E F ), up to 8 V; each oxide thus obtained was aged by keeping the system polarized at E F until the current reached an approximately constant value. 12 This experimental procedure was carried out using an Autolab PGSTAT 30 potentiostat/galvanostat from Eco Chemie, controlled by the GPES software.…”
Section: Methodsmentioning
confidence: 99%
“…Studies done in our laboratory 12 on the stability of anodic oxides grown on zirconium and its biocompatible alloys Ti-50Zr at.% and Zr-2.5Nb wt.%, in aerated Ringer physiological solution, showed that the stability of these oxides is increased by aging under potentiostatic conditions and decreased by the presence of chloride ions in the electrolyte during the anodization process. More recently, we also reported that, in solutions simulating physiologic media (Ringer and phosphate buffered saline (PBS) solutions), the Ti-50Zr at.% alloy has a better corrosion protection than the Zr-2.5Nb wt.% alloy or pure Zr.…”
Section: Introductionmentioning
confidence: 99%
“…This film provides a barrier between the metal and the medium. Typical values of the initial thickness of these oxide films are in the range of 2-5 nm, when formed in air at room temperature, but the thickness of the films can be increased by thermal oxidation or by anodic oxidation [1]. Oxide materials have an abundance of interesting physical properties that can be used for various technological applications.…”
Section: Introductionmentioning
confidence: 99%