1997
DOI: 10.1590/s0103-50531997000500015
|View full text |Cite
|
Sign up to set email alerts
|

Development of a flow injection system with two analytical paths for ammonium determination in soil extracts by conductometry

Abstract: Um sistema de análise química em fluxo com dois percursos analíticos foi desenvolvido para determinação de amônio em extratos de solo por condutometria. A amônia era gerada em linha em um meio alcalino, permeava através de uma membrana hidrofóbica (TPFE), sendo coletada em fluxo de água desionizada que transportava o analito para a cela de condutividade. O módulo de análise compreendia dois percursos analíticos independentes, para aumentar a frequência de amostragem. O sistema foi utilizado para determinar amô… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0
13

Year Published

2003
2003
2021
2021

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 43 publications
(33 citation statements)
references
References 7 publications
(13 reference statements)
0
20
0
13
Order By: Relevance
“…In addition, an automatic rain sensors based on a conductometric sensor was proposed by Gutz and co-workers, 205 and Krug and co-workers. 206 Tubino and Barros 207 have also described a conductometric sensor coupled to a flow injection system to measure soil extracts and acidity in vinegars. Recently, the development of electrochemical sensors based on measurement of electrochemical admittance spectroscopy were also investigated by Stradiotto and co-workers.…”
Section: Conductometric Sensorsmentioning
confidence: 99%
“…In addition, an automatic rain sensors based on a conductometric sensor was proposed by Gutz and co-workers, 205 and Krug and co-workers. 206 Tubino and Barros 207 have also described a conductometric sensor coupled to a flow injection system to measure soil extracts and acidity in vinegars. Recently, the development of electrochemical sensors based on measurement of electrochemical admittance spectroscopy were also investigated by Stradiotto and co-workers.…”
Section: Conductometric Sensorsmentioning
confidence: 99%
“…Total metals were determined with a series 6000 inductively coupled plasma optical emission spectrometer (ICP OES) from Thermo Scientific (Waltham, USA). Total hardness was determined by ethylenediaminetetraacetic acid (EDTA) titration, 25 and ammonia (NH 3 -N) obtained by calculation, taking into account the ammonium ion quantification (NH 4 -N) determined by flow injection conductometry, 26 as well as pH and temperature of the water samples. 23 The NH 3 contents were estimated based on the reversible reactions between NH 4 and NH 3 assessed by the pH values and aquarium temperatures during water sample collections.…”
Section: Methodsmentioning
confidence: 99%
“…Measurements of the standard ammonia concentration in the air were taken in a fallow area, i.e., without plants. The amount of NH 4 + was measured by flux injection analyses (FIA), as described by Reis et al (1997).…”
Section: Experiments 2 Growing Conditions and Experimental Designmentioning
confidence: 99%