Incorporation and voltammetric determination of silver (I) at an electrode electrochemically modified with a poly-benzidine film

Abstract: Eletrodos modificados com filmes de poli-bendizina são quimicamente estáveis no intervalo de pH en tre 0 e 7 e podem ser ciclados de -0.200 a 0.850 V sem evidência de decomposição. Conseqüentemente, neste intervalo de potencial, eles podem ser usados como ma te rial eletródico para a oxidação ou redução de diferentes espécies. Uma propriedade interessante deste eletrodo modificado é sua capacidade de capturar e quantificar o íon Ag(I) presente na solução. Para obter resultados reproduzíveis a etapa de acumulaç… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

1998
1998
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…[8] The benzidine rearrangement was a "cause celebre" in organic chemistry for many years. Initial hypotheses for the mechanism were put forward in the 1930s and 1940s, and an extraordinarily large amount of work as been devoted to these rearrangements both with hydrazobenzene and different aromatic hydrazo compounds.…”
Section: Introductionmentioning
confidence: 99%
“…[8] The benzidine rearrangement was a "cause celebre" in organic chemistry for many years. Initial hypotheses for the mechanism were put forward in the 1930s and 1940s, and an extraordinarily large amount of work as been devoted to these rearrangements both with hydrazobenzene and different aromatic hydrazo compounds.…”
Section: Introductionmentioning
confidence: 99%
“…The voltammetric analysis of ionic silver in bulk aqueous samples has been extensively studied, especially for low concentrations. [1][2][3][4][5][6][7][8][9] The methods include preconcentration of silver at carbon-based electrodes using silver complexing agents [2][3][4][5][6][7][8] and polymer films. [7][8][9] The objective of the work reported here was to design measurement strategies that would permit the direct (i.e.…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3][4][5][6][7][8][9] The methods include preconcentration of silver at carbon-based electrodes using silver complexing agents [2][3][4][5][6][7][8] and polymer films. [7][8][9] The objective of the work reported here was to design measurement strategies that would permit the direct (i.e. undiluted sample) determination of ionic silver over the wide concentration range required in the photographic industry.…”
Section: Introductionmentioning
confidence: 99%
“…This fouling of Pt electrodes (the same behavior was not evidenced on GC or C‐SPE) is probably due to the adsorption of the products of the reaction of polymerization of benzidine, which occurs in such experimental conditions 41. In order to protect Pt‐SPE from fouling, they were covered with a thin layer of Nafion membrane 38, 40.…”
Section: Resultsmentioning
confidence: 92%