2011
DOI: 10.1590/s0103-17592011000300001
|View full text |Cite
|
Sign up to set email alerts
|

Modeling and control of a three-phase isolated grid-connected converter for photovoltaic applications

Abstract: This paper describes the modeling and control of a three-phase grid-connected converter fed by a photovoltaic array. The converter is composed of an isolated DC-DC converter and a three-phase DC-AC voltage source inverter The converters are modeled in order to obtain small-signal transfer functions that are used in the design of three closed-loop controllers: for the output voltage of the PV array, the DC link voltage and the output currents. Simulated and experimental results are presented.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
5

Year Published

2012
2012
2017
2017

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 9 publications
(10 reference statements)
0
9
0
5
Order By: Relevance
“…M 1 , M 2 , M 3 dan M 4 are respectively driven by four Gate Driver Devices, i.e. E 1 , E 2 , E 3 dan E 4 . In general, we can also use insulated-gate bipolar transistors or IGBT [9] as the switching devices.…”
Section: A Circuit Modeling Using Spicementioning
confidence: 99%
See 1 more Smart Citation
“…M 1 , M 2 , M 3 dan M 4 are respectively driven by four Gate Driver Devices, i.e. E 1 , E 2 , E 3 dan E 4 . In general, we can also use insulated-gate bipolar transistors or IGBT [9] as the switching devices.…”
Section: A Circuit Modeling Using Spicementioning
confidence: 99%
“…Inverver can be classified in accordancee with its domain of applications, the way its output is controlled, the number of output phases, output voltage handling, and output waveform [1], [2]. According to its phase number, inverter can be classified into three-phase [2], [4] and single-phase inverter [3], [5]. Single-phase inverters can have pure sine waveform [3] generates high total harmonic distortion (THD).…”
Section: Introductionmentioning
confidence: 99%
“…Fig. 1 shows a simplified scheme of the control system employed for controlling the DC-DC and DC-AC converters [5] [6]. The first control block is responsible for tracking the array maximum output power (MPPT) and regulating the PV array voltage by controlling the switching of the DC-DC converter.…”
Section: Description Of the Two-stage Grid-tie Invertermentioning
confidence: 99%
“…Figure 1 [4] shows a two-stage PV inverter composed of cascaded DC-DC and DC-AC converters. The isolation transformer may be a low-frequency one placed at the output of the DC-AC converter, however the usage of a high-frequency transformer in the DC-DC converter is preferred for reducing size and weight [5].…”
Section: Introductionmentioning
confidence: 99%
“…Control of three-phase or single-phase bidirectional converters always have the same structure with two control loops. In systems not having energy storage at DCbus, inner current loop is used to regulate the current at the point of common coupling (PCC) corresponding to the interactive power and outer voltage loop to hold voltage at DCbus at a fixed value [8], [10].…”
Section: Introductionmentioning
confidence: 99%