2010
DOI: 10.1590/s0102-261x2010000400018
|View full text |Cite
|
Sign up to set email alerts
|

Avaliação de recursos geotermais da Bacia do Paraná

Abstract: RESUMO.Os resultados obtidos neste trabalho de Doutorado representam a primeira avaliação em escala regional de recursos geotermais da Bacia do Paraná. O trabalho se baseou na reavaliação de diversos estudos anteriores constantes na literatura e de aquisições complementares de dados nos Estados de São Paulo, Paraná, Santa Catarina, Goiás e Minas Gerais, o que permitiu avanços na qualidade e na quantidade das informações geotérmicas e melhorias na sua análise e interpretação. Os resultados indicam que os gradie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
2

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 0 publications
0
4
0
2
Order By: Relevance
“…Geothermal gradient and temperature Gomes (2009) presents data of geothermal gradient for Irati Formation calculated through the bottomhole temperature (BHT) method (Carvalho and Vacquier 1977), for the 2-TB-1-SP well resulting in a gradient of 20.4 ºC/km with a standard deviation of 1.02. The CO 2 reservoir of this study presents a geothermal gradient below 30 ºC/km, as recommended by international literature (IEA-GHG 2009; Miocic et al 2016).…”
Section: Porosity and Permeabilitymentioning
confidence: 99%
“…Geothermal gradient and temperature Gomes (2009) presents data of geothermal gradient for Irati Formation calculated through the bottomhole temperature (BHT) method (Carvalho and Vacquier 1977), for the 2-TB-1-SP well resulting in a gradient of 20.4 ºC/km with a standard deviation of 1.02. The CO 2 reservoir of this study presents a geothermal gradient below 30 ºC/km, as recommended by international literature (IEA-GHG 2009; Miocic et al 2016).…”
Section: Porosity and Permeabilitymentioning
confidence: 99%
“…Gomes 67 presented the geothermal gradient of 20.4 ºC/km with a standard deviation of 1.02 calculated through the bottom-hole temperature (BHT) method, 68 for the Irati Formation in the well 2-TB-1-SP. The geothermal gradient is suitable for CO 2 storage considering recommended range (below 30 ºC/km) based on existing atlases.…”
Section: Geothermal Gradient and Temperaturementioning
confidence: 99%
“…The approach assumed for this initial assessment of the Irati Formation shale reservoir was quite conservative. The study engaged the CO 2 density of 842.3 kg/m 3 at supercritical conditions considering the geothermal gradient of 20.4 ºC/km, 67 an average depth of 2.640 m from the well 2-TB-1-SP, and an assumed hydrostatic gradient of 10.7 kPa/m for capacity estimation.…”
Section: Capacity Estimation and Classificationmentioning
confidence: 99%
“…A título de comparação, Hamza e Eston (1981) e Hamza et al (2005), propuseram taxas de aumentos de temperaturas na bacia do Paraná de cerca de 1º C para cada 30 metros de profundidade ou 33º C por quilômetro. Paralelamente o DAEE utilizou a seguinte equação linear para projetar as temperaturas das águas do aquífero Guarani: 20 * 02877 , 0   x y (2) Na equação (2) acima y representa temperatura das águas, x é a espessura do basalto (Formação Serra Geral) e o fator 20 representa a temperatura média anual da superfície.…”
Section: Discussões E Conclusõesunclassified
“…De acordo com Zalán e Oliveira (2005), há ocorrência de uma pequena intrusão alcalina, no local de coordenadas aproximadas de 45,6º longitude oeste por 22,76º latitude sul, distante a menos de 40 quilômetros da área anômala. As evidências geológicas complementares indicam existências de outras intrusões mais próximas, também de pequeno porte, que potencialmente podem ter contribuí-do para a caracterização da anomalia estudada, justificando o aumento da temperatura e o consequente grau geotérmico mais elevado.…”
Section: Discussões E Conclusõesunclassified