2008
DOI: 10.1590/s0102-261x2008000400013
|View full text |Cite
|
Sign up to set email alerts
|

O método transiente eletromagnético (tem) aplicado ao imageamento geoelétrico da bacia de resende (RJ, Brasil)

Abstract: This work presents an application of the Transient Electromagnetic geophysical method in the area of Basin of Resende, Rio de Janeiro, Brazil. In this basin, it was made in 2001, a geophysical survey of 88 soundings seeking to contribute for the knowledge of the hydrogeological potential of the area. This area is densely industrialized, so noise tends to hinder the use of the method. The data were interpreted using an 1-D inversion algorithm where the resistivity in depth is estimated from the induced voltage … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 1 publication
(1 reference statement)
0
4
0
Order By: Relevance
“…It is a segment covering Porto Real, Quatis, Barra Mansa (Floriano district), Resende and Itatiaia counties. The dimensions of the basin are 47 km long, 4.5 km average wide and 7.3 km at its widest portion in the west of Resende and 1.2 km minimum width in the west of Itatiaia (Santos & Flexor, 2008). It is located between the 22° 22 ' -22° 30' S latitude and 44°12' -44° 30' W longitude (Figure 7).…”
Section: Description Of the Resende Basin Locationmentioning
confidence: 99%
See 2 more Smart Citations
“…It is a segment covering Porto Real, Quatis, Barra Mansa (Floriano district), Resende and Itatiaia counties. The dimensions of the basin are 47 km long, 4.5 km average wide and 7.3 km at its widest portion in the west of Resende and 1.2 km minimum width in the west of Itatiaia (Santos & Flexor, 2008). It is located between the 22° 22 ' -22° 30' S latitude and 44°12' -44° 30' W longitude (Figure 7).…”
Section: Description Of the Resende Basin Locationmentioning
confidence: 99%
“…According to Santos & Flexor (2008), in the acquisition of the transient electromagnetic method data, the most commonly used settings are described in Figure 5.…”
Section: Ra Lmentioning
confidence: 99%
See 1 more Smart Citation
“…Santos and Flexor [15] used the 1D inversion of TEM soundings for hydrogeological studies at the Resende Basin, in a densely industrialized area and therefore with high levels of EM noise. A study about the effects of urban noise was carried out by Porsani et al [16], where TEM soundings with different electromagnetic moments were compared in order to evaluate the applicability of the method in similar environments.…”
Section: Introductionmentioning
confidence: 99%