2004
DOI: 10.1590/s0100-879x2004001100002
|View full text |Cite
|
Sign up to set email alerts
|

Bioelectrical impedance spectroscopy for the assessment of body fluid volumes of term neonates

Abstract: The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop specific equations for the neonatal population to determine body fluid compartments. Bioelectric impedance measuremen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0
6

Year Published

2010
2010
2016
2016

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 35 publications
0
8
0
6
Order By: Relevance
“…The measured impedance, corrected for the reactive component, known as electrical resistance is inversely and quantitatively related to the volume of conductive compartment which can be used to calculate total body water (TBW) and estimate fat-free mass (FFM) and fat mass (FM) (2). BIS provides reliable estimates of TBW in adults and equations have been developed for children and infants (3,4). While in very young infants (<5 mo) BIS is associated with poorer predictive performance that could be due to the higher conductivity of the infant's adipose tissue with its increased vascularization and water content, and rapidly changing hydration status caused by feeding patterns (4-6), small bias indicates that BIS is suitable for comparison between groups and for longitudinal studies (4).…”
mentioning
confidence: 99%
“…The measured impedance, corrected for the reactive component, known as electrical resistance is inversely and quantitatively related to the volume of conductive compartment which can be used to calculate total body water (TBW) and estimate fat-free mass (FFM) and fat mass (FM) (2). BIS provides reliable estimates of TBW in adults and equations have been developed for children and infants (3,4). While in very young infants (<5 mo) BIS is associated with poorer predictive performance that could be due to the higher conductivity of the infant's adipose tissue with its increased vascularization and water content, and rapidly changing hydration status caused by feeding patterns (4-6), small bias indicates that BIS is suitable for comparison between groups and for longitudinal studies (4).…”
mentioning
confidence: 99%
“…Studies in preterm and term infants have shown it to predict TBW accurately [39,40,41]. However, the rapid fluxes in TBW in preterm and newborn infants mean that its ability to accurately predict body composition in terms of FFM and FM is limited.…”
Section: Body Composition Methods Suitable For Paediatric Usementioning
confidence: 99%
“…Como, nos primeiros 28 dias de vida, o turnover de água no RN é muito grande, o mesmo torna-se susceptível a distúrbios hidroeletrolíticos. Conhecer detalhadamente a composição corporal durante o período pós-natal tardio pode ser importante para o cuidado nutricional e o tratamento 6,7 .…”
Section: Introductionunclassified