2014
DOI: 10.1590/s0100-736x2014000500014
|View full text |Cite
|
Sign up to set email alerts
|

QT interval in healthy dogs: which method of correcting the QT interval in dogs is appropriate for use in small animal clinics?

Abstract: Pesq. Vet. Bras. 34(5):469-472, maio 2014 469 RESUMO.-[Intervalo QT em cães hígidos: qual método de correção para o intervalo QT é mais apropriado na clínica de pequenos animais?] O intervalo QT do eletrocardiograma (ECG) é influenciado por variações da frequência cardíaca (FC), o que pode levar a erros na interpretação de sua duração. Considerando que as alterações na duração do intervalo QT refletem anormalidades da repolarização ventricular, as quais predispõem a ocorrência de arritmias, esta variável … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
4
2
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 27 publications
1
4
2
1
Order By: Relevance
“…QT correction was made using the Bazett, Fridericia and Van der Water formulas, and considering the high HR, QTcV showed less variability from the original QT thus suggesting that the Van der Water formula should be employed. That is in accordance with previous researchers (Spence et al 1998, Oliveira et al 2012. The need to establish a suitable QT correction formula relies on the importance to evaluate the occurrence of QT prolongation, which leads to fatal arrhythmias such as Torsade de Pointes (Hamlin et al 2003).…”
Section: Discussionsupporting
confidence: 87%
“…QT correction was made using the Bazett, Fridericia and Van der Water formulas, and considering the high HR, QTcV showed less variability from the original QT thus suggesting that the Van der Water formula should be employed. That is in accordance with previous researchers (Spence et al 1998, Oliveira et al 2012. The need to establish a suitable QT correction formula relies on the importance to evaluate the occurrence of QT prolongation, which leads to fatal arrhythmias such as Torsade de Pointes (Hamlin et al 2003).…”
Section: Discussionsupporting
confidence: 87%
“…These values were lower than the human standard (360 ms) [37] and higher than that found for wild cats (Leopardus tigrinus) (230 ms), which did not show differences between males and females [34]. This interval represents the complete duration of the ventricular electrical activity, and may be influenced by heart rate variations, in this case, showing a proportionally inverse relationship between the two parameters [35]. The QT interval for non-anesthetized agoutis was lower than for anesthetized agoutis.…”
Section: Discussionmentioning
confidence: 51%
“…Concerning the QT interval, this showed a high negative correlation with HR and a moderate negative correlation with BW. The QT interval is routinely used to measure the ventricular repolarization in human and veterinary medicine ( Al-Khatib et al , 2003 ; Pedersen et al , 2013 ; Oliveira et al , 2014 ). In humans and animals, QT interval is negatively correlated with HR, leading to a decrease in the interval when the HR increases ( Davey, 2002 ; Al-Khatib et al , 2003 ; Moss, 2003 ; Rajappan et al , 2003 , Rezakhani et al , 2004).…”
Section: Discussionmentioning
confidence: 99%