2014
DOI: 10.1590/s0100-69912014000300008
|View full text |Cite
|
Sign up to set email alerts
|

Standardization of pulmonary ventilation technique using volume-controlled ventilators in rats with congenital diaphragmatic hernia

Abstract: ABSTRACT ABSTRACT ABSTRACTObjective Objective Objective Objective Objective: To standardize a technique for ventilating rat fetuses with Congenital Diaphragmatic Hernia (CDH) using a volumecontrolled ventilator. Methods Methods Methods Methods Methods: Pregnant rats were divided into the following groups: a) control (C); b) exposed to nitrofen with CDH (CDH); and c) exposed to nitrofen without CDH (N-). Fetuses of the three groups were randomly divided into the subgroups ventilated (V) and non-ventilated (N-V)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 32 publications
0
4
0
1
Order By: Relevance
“…Our findings show a slightly larger difference in lung capacity than other existing reports. Gallindo et al 20 estimated that rodents with CDH should be ventilated at a tidal volume that was 67% that of control rodents, but their data were based on estimates of ideal tidal volumes based on visualization of successful chest rise. Flemmer et al 21 used FOT and found that CDH rabbits had inspiratory capacities roughly 70% that of control rabbits.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Our findings show a slightly larger difference in lung capacity than other existing reports. Gallindo et al 20 estimated that rodents with CDH should be ventilated at a tidal volume that was 67% that of control rodents, but their data were based on estimates of ideal tidal volumes based on visualization of successful chest rise. Flemmer et al 21 used FOT and found that CDH rabbits had inspiratory capacities roughly 70% that of control rabbits.…”
Section: Discussionmentioning
confidence: 99%
“…Our lab is collaborating with industry partners to test the effect of oxygen‐carrying nanoparticles and hypoxia pathway modulators on the SpO 2 of CDH rodents. For our team and in the existing literature, neonatal rodent tracheostomy had a steep learning curve, but can be achieved reliably and reproducibly 20 . FlexiVent and other rodent ventilation systems can record a variety of measurements using different ventilation parameters.…”
Section: Discussionmentioning
confidence: 99%
“…The PTV, PTAV, TV, and TAV subgroups were ventilated with a Mini-Vent type 845 mechanical mini-ventilator (Harvard Apparatus ® , Hugo Sachs Eletronik Harvard Apparatus GmbH, Germany), according to Gallindo et al ( 16 ). The newborn pups were positioned on a heated table where they were intubated with an intravascular teflon 24G Vialon™ catheter (BD Insyte Autoguard, Becton Dickinson Infusion Therapy System Inc., USA) utilizing a surgical microscope with 4.5× magnification (DFV, Vasconcellos, Brazil), with a continuous 100% oxygen (O 2 ) flow with a cycling frequency of 80 rpm, FiO 2 of 1.0, inspiratory/expiratory ratio of 1:1, and positive end expiratory pressure of 0 cmH 2 O, for 30 min.…”
Section: Methodsmentioning
confidence: 99%
“…A 24 G catheter was placed, connected to MiniVent type 845 (Hugo Sachs Elektronik-Harvard Apparatus GmbH, March-Hugstetten, Germany), with a frequency of 80 breaths per minute, FiO2 1.0, inspiration-expiration ratio 1:1, and PEEP 0 cmH2O. The tidal volume was 13.5 ml/kg in the control groups (75 µl) and 9 ml/kg (50 µl) in the groups with CDH, based on a previous study by our laboratory (18). Non-ventilated animals were delivered by cesarian section, weighted, and immediately euthanized.…”
Section: Harvestmentioning
confidence: 99%